{"title":"Bilge Pumps","description":"","products":[{"product_id":"johnson-spx-flow-l1600-heavy-duty-submersible-bilge-pump","title":"Johnson SPX Flow L1600 Heavy Duty Submersible Bilge Pump","description":"\u003cp\u003eThe best choice when you are looking for a high performance, heavy duty bilge pump that is designed to meet \u0026amp; exceed the tough demands of commercial \u0026amp; recreational duty.\u003c\/p\u003e\n\u003cp\u003eThis pump has a liquid cooled, 12-pole motor with double ball bearings for extended service life. The L2200 motor is sealed off by a mechanical seal that eliminates shaft wear \u0026amp; allows for service \u0026amp; replacement, while the L1600 has a lip seal.\u003c\/p\u003e\n\u003cp\u003eThe L4000 high capacity, heavy duty bilge pump has been developed by Johnson Pump as the premier pump in our submersible bilge pump range. Featuring a robust motor design, mechanical shaft seal, high impact ABS plastic and unique threaded port design, the L4000 will out perform all other comparable pumps on the market.\u003c\/p\u003e\n\u003cp\u003eUniversal base plate and a choice of 1.1⁄2\" or 2\" ports makes for a simple installation. All pumps include a removable check valve.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCapacities of 1600 GPH\u003c\/li\u003e\n\u003cli\u003eLiquid cooled, 12-pole motor with double ball bearings for extended service life\u003c\/li\u003e\n\u003cli\u003eShaft of stainless steel (SS2343)\u003c\/li\u003e\n\u003cli\u003eImpeller is carefully designed and tested to maximize head and flow\u003c\/li\u003e\n\u003cli\u003eUniversal base plate and choice of two different ports makes for a simple installation\u003c\/li\u003e\n\u003cli\u003eRemovable check valve included\u003c\/li\u003e\n\u003cli\u003eHeavy Duty Submersible Pumps can be combined with either an electronic float switch or the Ultima Switch for automatic operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable data-sheets-baot=\"1\" data-sheets-root=\"1\" border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"272\"\u003e \u003ccol width=\"272\"\u003e \u003ccol width=\"272\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Description\u003c\/td\u003e\n\u003ctd\u003e100 LPM (1600 GPH)\u003c\/td\u003e\n\u003ctd\u003e100 LPM (1600 GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Bilge Pumps\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHose Size\u003c\/td\u003e\n\u003ctd\u003e1-1\/8\" \u0026amp; 1-1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1-1\/8\" \u0026amp; 1-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eJohnson\u003c\/td\u003e\n\u003ctd\u003eJohnson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eL1600\u003c\/td\u003e\n\u003ctd\u003eL1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Description\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Description\u003c\/td\u003e\n\u003ctd\u003e7A\u003c\/td\u003e\n\u003ctd\u003e3.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Johnson","offers":[{"title":"12v","offer_id":55862940303737,"sku":"AF-10-1600-01","price":124.99,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":55862940336505,"sku":"AF-10-1600-02","price":129.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/10-1600-01y.jpg?v=1695815032"},{"product_id":"attwood-tsunami-bilge-pump-1200-gph-12-volt-ma-4612-7","title":"Attwood Tsunami Bilge Pump 1200 GPH 12 Volt","description":"\u003cp\u003eAttwood Tsunami Bilge Pump 1200 GPH 12 Volt.  Ref17:  MA-4612-7\n\u003c\/p\u003e\n\u003cp\u003e Tsunami bilge pump deliver powerful water output in 500 gph, 800 gph and 1200 gph capacities.  They circulate around the pump motor housing, helping to absorb the heat given off by the operating motor.  The patented shaft seal centres directly on the motor shaft, preventing leaks caused by misalignment.  The moulded two wire seal is permanently fused to the  insulation to prevent a leak path.  Wiring is caulked and tinned to eliminate wicking, prevent water damage and resist corrosion.  Secured directly to the hull - no bracket required.  All pump housings are made of a rugged glass and mineral filled polymer that withstands hull pounding and resists chemical.  Not just fuel, oil and detergents that accumulate in teh bilge, but also the plasticizer used in most hoses.  These plasticizers can break down the chemical composition of the materials used in other pumps.\n\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel No:  T1200\u003c\/li\u003e\n  \u003cli\u003eWater Output:  1200gph\u003c\/li\u003e\n  \u003cli\u003eAmp Draw:  3.5\u003c\/li\u003e\n  \u003cli\u003eFuse Size:  5\u003c\/li\u003e\n  \u003cli\u003eHose Size:  28.5mm (1 1\/8\")\u003c\/li\u003e\n  \u003cli\u003eHeight:  111mm (4 3\/8\")\u003c\/li\u003e\n  \u003cli\u003eWidth:  79mm (3 1\/8\")\n  \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.attwoodmarine.com\/userfiles\/store\/product\/image\/files\/1218\/tsunamibilge-spec.pdf\"\u003eTechnical Specification\u003c\/a\u003e\n\u003c\/p\u003e \u003ca href=\"http:\/\/www.attwoodmarine.com\/userfiles\/store\/product\/image\/files\/1218\/69390-tsunami-bilge-pump-instr.pdf\"\u003eInstallation Instructions\u003c\/a\u003e\n\u003cul\u003e\n\u003c\/ul\u003e","brand":"Attwood","offers":[{"title":"Default Title","offer_id":46488877957397,"sku":"MA-4612-7","price":58.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/4612.jpg?v=1695911892"},{"product_id":"attwood-tsunami-bilge-pump-500-gph-12-volt-ma-4606-7","title":"Attwood Tsunami Bilge Pump 500 GPH - 12 Volt","description":"\u003cp\u003eAttwood Tsunami Bilge Pump 500 GPH 12 Volt.  Ref17:  MA-4606-7\u003c\/p\u003e\n\n\u003cp\u003eTsunami bilge pump deliver powerful water output in 500 gph.  They circulate around the pump motor housing, helping to absorb the heat given off by the operating motor.  The patented shaft seal centres directly on the motor shaft, preventing leaks caused by misalignment.  The moulded two wire seal is permanently fused to the  insulation to prevent a leak path.  Wiring is caulked and tinned to eliminate wicking, prevent water damage and resist corrosion. \u003c\/p\u003e\n\n\u003cp\u003eSecured directly to the hull - no bracket required.  All pump housings are made of a rugged glass and mineral filled polymer that withstands hull pounding and resists chemical.  Not just fuel, oil and detergents that accumulate in the bilge, but also the plasticizer used in most hoses.  These plasticizers can break down the chemical composition of the materials used in other pumps.\u003c\/p\u003e\n\n\u003cp\u003eSpecification:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eModel No:  T500\u003c\/li\u003e\n\t\u003cli\u003eWater Output:  500 GPH\u003c\/li\u003e\n\t\u003cli\u003eAmp Draw:  1.5\u003c\/li\u003e\n\t\u003cli\u003eWire\/Connector: 29\"\u003c\/li\u003e\n\t\u003cli\u003eAmp Draw: 1.8\u003c\/li\u003e\n\t\u003cli\u003eMax Head: 9 ft\u003c\/li\u003e\n\t\u003cli\u003eFuse Size: 3 Amp \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDimensions:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eA: 70mm\u003c\/li\u003e\n\t\u003cli\u003eB: 73mm\u003c\/li\u003e\n\t\u003cli\u003eC: 92mm\u003c\/li\u003e\n\t\u003cli\u003eD (Hose Size): 19mm (3\/4\")\u003c\/li\u003e\n\t\u003cli\u003eE: 80mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cimg alt=\"\" src=\"\/image\/product\/attwood\/4606-7.jpg\" style=\"float:centre; height:300px; width:300px\"\u003e\u003c\/p\u003e","brand":"Attwood","offers":[{"title":"Default Title","offer_id":46488878579989,"sku":"MA-4606-7","price":44.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/4606c.jpg?v=1695911657"},{"product_id":"attwood-tsunami-bilge-pump-800-gph-12-volt-ma-4608-1","title":"Attwood Tsunami Bilge Pump 800 GPH 12 Volt","description":"\u003cp\u003eAttwood Tsunami Bilge Pump 800 GPH 12 Volt.  Ref17:  MA-4608-1\u003c\/p\u003e\n\n\u003cp\u003eTsunami bilge pump deliver powerful water output in 500 gph, 800 gph and 1200 gph capacities.  They circulate around the pump motor housing, helping to absorb the heat given off by the operating motor.  The patented shaft seal centres directly on the motor shaft, preventing leaks caused by misalignment.  The moulded two wire seal is permanently fused to the  insulation to prevent a leak path.  Wiring is caulked and tinned to eliminate wicking, prevent water damage and resist corrosion.  Secured directly to the hull - no bracket required.  All pump housings are made of a rugged glass and mineral filled polymer that withstands hull pounding and resists chemical.  Not just fuel, oil and detergents that accumulate in teh bilge, but also the plasticizer used in most hoses.  These plasticizers can break down the chemical composition of the materials used in other pumps.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eModel No:  T800\u003c\/li\u003e\n\t\u003cli\u003eWater Output:  800gph\u003c\/li\u003e\n\t\u003cli\u003eAmp Draw:  3.0\u003c\/li\u003e\n\t\u003cli\u003eFuse Size:  4\u003c\/li\u003e\n\t\u003cli\u003eHose Size:  19mm (3\/4\")\u003c\/li\u003e\n\t\u003cli\u003eHeight:  111mm (4 3\/8\")\u003c\/li\u003e\n\t\u003cli\u003eWidth:  79mm (3 1\/8\")\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"http:\/\/www.attwoodmarine.com\/userfiles\/store\/product\/image\/files\/1218\/tsunamibilge-spec.pdf\"\u003eTechnical Specification\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"http:\/\/www.attwoodmarine.com\/userfiles\/store\/product\/image\/files\/1218\/69390-tsunami-bilge-pump-instr.pdf\"\u003eInstallation Instructions\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003c\/ul\u003e","brand":"Attwood","offers":[{"title":"Default Title","offer_id":46488878809365,"sku":"MA-4608-1","price":50.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/4608.jpg?v=1695911809"},{"product_id":"attwood-water-buster-cordless-pump-ma-4140-4","title":"Attwood Water Buster Cordless Pump","description":"\u003cp\u003eAttwood Water Buster Cordless Pump. Ref17: MA-4140-4\u003c\/p\u003e\n\n\u003cp\u003eThis submersible pump is a great way to remove unwanted water from boats, pool covers, aquariums and sump pits. Convenient and safe, too, because it needs no electrical cord – runs up to 5 hours on three alkaline D batteries. Excellent for use as a portable pump-out device for paddle boats, inflatables, duck boats, dinghies and kayaks. Any craft that lacks a hard-wire, permanent electrical system.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e6-3\/8\" high x 5-1\/4\"\u003c\/li\u003e\n\t\u003cli\u003ePumps up to 200 gallons per hour\u003c\/li\u003e\n\t\u003cli\u003eIncludes 42\" hose with garden-hose adapter for adding longer hose\u003c\/li\u003e\n\t\u003cli\u003eLifts water to height of 40\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"http:\/\/www.attwoodmarine.com\/userfiles\/store\/product\/image\/files\/83\/69243-waterbusterinstr-ri.pdf\"\u003eInstallation Instructions\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003c\/ul\u003e","brand":"Attwood","offers":[{"title":"Default Title","offer_id":46488880742677,"sku":"MA-4140-4","price":100.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/4140.jpg?v=1695911805"},{"product_id":"hand-operated-bilge-stirrup-pump","title":"Hand Operated Bilge Stirrup Pump","description":"\u003cp\u003eAll PVC construction. Nothing to corrode!\u003c\/p\u003e\n\u003cp\u003eHand Operated Bilge Stirrup Pump. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBody Length 660mm\u003c\/li\u003e\n\u003cli\u003eHose Length 610mm\u003c\/li\u003e\n\u003cli\u003e4.8 liters per 10 strokes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"C-Quip","offers":[{"title":"Default Title","offer_id":46489184370965,"sku":"CQ-10-17141","price":15.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/files\/CQ-10-17141.jpg?v=1695912337"},{"product_id":"jabsco-junior-puppy-23670-series-bilge-deckwash-pump","title":"Jabsco Junior Puppy 23670 Series Bilge \u0026 Deckwash Pump","description":"\u003cp\u003eThe \u003cstrong\u003eJabsco 23670 Junior Puppy\u003c\/strong\u003e is a bronze-bodied, self-priming flexible-impeller pump delivering approximately 15 litres per minute. Choose 12V model 23670-4003 or 24V model 23670-4103.\u003c\/p\u003e\u003cp\u003eThe continuously rated pump is intended for medium-duty bilge, deckwash and general water-transfer applications. Its simple serviceable design uses a nitrile impeller and stainless-steel shaft, and it must be mounted so the pump head is not positioned above the motor.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Jabsco\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Jabsco 23670 Junior Puppy Bilge and Deckwash Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 23670-4003, 23670-4103\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-23670-4003, CW-23670-4103\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Self-priming flexible-impeller utility pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One selected product or kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Jabsco Junior Puppy Used For?\u003c\/h4\u003e\u003cp\u003eIt transfers water for bilge pumping, deck washing and other medium-duty marine or industrial duties where a self-priming 15 LPM pump is suitable.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Jabsco 23670 Junior Puppy pump in the selected voltage\u003c\/li\u003e\n\u003cli\u003eFactory-fitted nitrile flexible impeller\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eHose or pipework, clips and through-hull fittings\u003c\/li\u003e\n\u003cli\u003eCircuit-protection fuse or breaker\u003c\/li\u003e\n\u003cli\u003eCable extensions and waterproof electrical connectors\u003c\/li\u003e\n\u003cli\u003eControl switch unless specifically listed as included\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Products or Systems Is This Compatible With?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e12V or 24V DC systems according to the selected model\u003c\/li\u003e\n\u003cli\u003e19 mm (3\/4 in) bore hose\u003c\/li\u003e\n\u003cli\u003e3\/8 in BSP female threaded connections\u003c\/li\u003e\n\u003cli\u003eWater-transfer duties compatible with bronze, nitrile and stainless-steel wetted materials\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Do I Select the Correct Model or Confirm Compatibility?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSelect 23670-4003 for 12V or 23670-4103 for 24V\u003c\/li\u003e\n\u003cli\u003eAllow for the model-specific current draw and fuse\u003c\/li\u003e\n\u003cli\u003eConfirm that approximately 15 LPM meets the required duty at the installed head\u003c\/li\u003e\n\u003cli\u003eDo not use for petrol or liquids with a flash point below 37°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBronze pump body\u003c\/li\u003e\n\u003cli\u003eNitrile flexible impeller\u003c\/li\u003e\n\u003cli\u003eStainless-steel shaft\u003c\/li\u003e\n\u003cli\u003eLip-seal construction\u003c\/li\u003e\n\u003cli\u003eServiceable flexible-impeller design\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eIsolate the electrical supply before installation. Match the pump to the vessel voltage, use the specified circuit protection and cable size, keep electrical joints dry and accessible, and support all connected hose or pipework. Follow the Jabsco installation instructions for mounting orientation, priming and duty cycle.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect the pump, wiring, fuse, ports and connected pipework regularly. Clean any inlet strainer, investigate reduced flow or repeated fuse failure, and replace worn seals, diaphragms or impellers with the correct Jabsco service parts.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eApprox. 15 LPM output\u003c\/li\u003e\n\u003cli\u003e12V and 24V variants\u003c\/li\u003e\n\u003cli\u003eSelf-primes up to 2.5 m\u003c\/li\u003e\n\u003cli\u003e19 mm hose or 3\/8 in BSP connections\u003c\/li\u003e\n\u003cli\u003eContinuously rated medium-duty design\u003c\/li\u003e\n\u003cli\u003eISO 8846 and ISO 8849 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eCan the Junior Puppy run dry?\u003c\/strong\u003e\u003cbr\u003eNo. Flexible-impeller pumps can be damaged by dry running; ensure the pump is primed and the inlet path is clear.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this an automatic bilge pump?\u003c\/strong\u003e\u003cbr\u003eNo. It requires a separate correctly rated switch or control arrangement.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I know whether this part is compatible?\u003c\/strong\u003e\u003cbr\u003eMatch the exact Jabsco model or part number first, then confirm the connection size, voltage, dimensions and application shown in the specification table.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAre installation accessories included?\u003c\/strong\u003e\u003cbr\u003eOnly the components listed under “What Is Included?” are supplied. Hose, wiring, fittings, switches and fasteners are excluded unless stated otherwise.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable class=\"spec-table\" style=\"width:100%;border-collapse:collapse;font-family:Roboto, Arial, sans-serif;background:#ffffff;text-align:center;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:center;font-weight:500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:center;font-weight:500;\"\u003e23670-4003\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:center;font-weight:500;\"\u003e23670-4103\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eJabsco\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eJabsco\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eSelf-priming flexible-impeller utility pump\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eSelf-priming flexible-impeller utility pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eCW-23670-4003\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eCW-23670-4103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eMaximum flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eApprox. 15 LPM\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eApprox. 15 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e13A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eFlow at 5 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e930 LPH (245 US GPH)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e930 LPH (245 US GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eFlow at 10 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e810 LPH (213 US GPH)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e810 LPH (213 US GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eFlow at 15 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e690 LPH (182 US GPH)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e690 LPH (182 US GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eSelf-priming lift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eUp to 2.5 m\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eUp to 2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e19 mm (3\/4 in) hose or 3\/8 in BSP female\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e19 mm (3\/4 in) hose or 3\/8 in BSP female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e180 x 110 x 90 mm (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e180 x 110 x 90 mm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eReplacement impeller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e9200-0023B\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e9200-0023B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eISO 8846 ignition protection; ISO 8849 bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eISO 8846 ignition protection; ISO 8849 bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003cem\u003ePerformance depends on total head, hose condition, voltage at the motor and the condition of the flexible impeller.\u003c\/em\u003e\u003c\/p\u003e","brand":"Jabsco","offers":[{"title":"12v","offer_id":54832707142009,"sku":"ASAP-JAB-23670-4003","price":334.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54832707174777,"sku":"ASAP-JAB-23670-4103","price":334.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/23670_jpg.jpg?v=1695911961"},{"product_id":"jabsco-water-puppy-2000-bilge-deckwash-pump","title":"Jabsco Water Puppy 2000 23680 Series Bilge \u0026 Deckwash Pump","description":"\u003cp\u003eThe \u003cstrong\u003eJabsco Water Puppy 2000\u003c\/strong\u003e is a non-automatic, self-priming flexible-impeller pump for bilge and deckwash duties, available for 12V or 24V systems with 25 mm hose connections.\u003c\/p\u003e\u003cp\u003eIts bronze pump body and serviceable impeller head provide strong suction for intermittent bilge pumping, deck washing and compatible water transfer. A separate switch is required for automatic bilge control.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Jabsco\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Jabsco Water Puppy 2000 Bilge and Deckwash Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 23680-4003, 23680-4103\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-23680-4003, CW-23680-4103\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Flexible-impeller bilge and deckwash pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One selected product or kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Jabsco Water Puppy 2000 Used For?\u003c\/h4\u003e\u003cp\u003eIt is used for bilge drainage, deck washing and general water transfer where a self-priming remote pump is required.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Water Puppy 2000 pump in the selected voltage\u003c\/li\u003e\n\u003cli\u003eFactory-fitted electrical leads\u003c\/li\u003e\n\u003cli\u003eFlexible impeller installed in the pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eHose or pipework, clips and through-hull fittings\u003c\/li\u003e\n\u003cli\u003eCircuit-protection fuse or breaker\u003c\/li\u003e\n\u003cli\u003eCable extensions and waterproof electrical connectors\u003c\/li\u003e\n\u003cli\u003eControl switch unless specifically listed as included\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Products or Systems Is This Compatible With?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e12V or 24V DC systems according to model\u003c\/li\u003e\n\u003cli\u003e25 mm (1 in) hose or 1\/2 in BSP female pipe connections\u003c\/li\u003e\n\u003cli\u003eManual switching or a suitably rated automatic bilge control\u003c\/li\u003e\n\u003cli\u003eCompatible water and bilge-water applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Do I Select the Correct Model or Confirm Compatibility?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eChoose 23680-4003 for 12V or 23680-4103 for 24V\u003c\/li\u003e\n\u003cli\u003eAllow for 15A fuse protection on 12V and 10A on 24V\u003c\/li\u003e\n\u003cli\u003eUse 25 mm hose throughout the discharge path\u003c\/li\u003e\n\u003cli\u003eConfirm the expected output at the actual discharge head\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBronze flexible-impeller pump head\u003c\/li\u003e\n\u003cli\u003eStainless-steel shaft\u003c\/li\u003e\n\u003cli\u003eServiceable nitrile impeller\u003c\/li\u003e\n\u003cli\u003eDC motor for intermittent marine duty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eIsolate the electrical supply before installation. Match the pump to the vessel voltage, use the specified circuit protection and cable size, keep electrical joints dry and accessible, and support all connected hose or pipework. Follow the Jabsco installation instructions for mounting orientation, priming and duty cycle.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect the pump, wiring, fuse, ports and connected pipework regularly. Clean any inlet strainer, investigate reduced flow or repeated fuse failure, and replace worn seals, diaphragms or impellers with the correct Jabsco service parts.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e12V and 24V versions\u003c\/li\u003e\n\u003cli\u003eSelf-primes to approximately 1.2 m\u003c\/li\u003e\n\u003cli\u003e25 mm hose connections\u003c\/li\u003e\n\u003cli\u003eNon-automatic remote pump design\u003c\/li\u003e\n\u003cli\u003eISO 8846 ignition protected\u003c\/li\u003e\n\u003cli\u003eISO 8849 marine bilge-pump compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eIs this an automatic bilge pump?\u003c\/strong\u003e\u003cbr\u003eNo. Add a correctly rated float switch or control system where automatic operation is required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat replacement impeller is listed?\u003c\/strong\u003e\u003cbr\u003eThe source listing specifies Jabsco 6303-0001-P; confirm against the pump service documentation before ordering.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I know whether this part is compatible?\u003c\/strong\u003e\u003cbr\u003eMatch the exact Jabsco model or part number first, then confirm the connection size, voltage, dimensions and application shown in the specification table.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAre installation accessories included?\u003c\/strong\u003e\u003cbr\u003eOnly the components listed under “What Is Included?” are supplied. Hose, wiring, fittings, switches and fasteners are excluded unless stated otherwise.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable class=\"spec-table\" style=\"width:100%;border-collapse:collapse;font-family:Roboto, Arial, sans-serif;background:#ffffff;text-align:center;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:center;font-weight:500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:center;font-weight:500;\"\u003e23680-4003\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:center;font-weight:500;\"\u003e23680-4103\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eJabsco\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eJabsco\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eFlexible-impeller bilge and deckwash pump\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eFlexible-impeller bilge and deckwash pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eCW-23680-4003\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eCW-23680-4103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eISO8846 marine (ignition), ISO8849 marine (bilge pump) standards.\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eISO8846 marine (ignition), ISO8849 marine (bilge pump) standards.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eFuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eHeight Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e75mm (3\")\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e75mm (3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e195mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e195mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eWater Puppy 2000\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eWater Puppy 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eVoltage Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e120mm (4.75\")\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e120mm (4.75\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eAutomatic Bilge Pumps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eFlow Rate 2 Metre Head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e2100LPH (554 US GPH)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e2100LPH (554 US GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eFlow Rate 3 Metre Head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e1920LPH (507 US GPH)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e1920LPH (507 US GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eFlow Rate 6 Metre Head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e1500LPH (396 US GPH)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e1500LPH (396 US GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eHose Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e25mm \/ 1\"\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e25mm \/ 1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eReplacement Impeller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eJAB-6303-0001-P\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eJAB-6303-0001-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eSelf Primes up to\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e1.2 Metres (4 Feet)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e1.2 Metres (4 Feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eInlet Outlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eFor 25mm (1\") ID Hose \u0026amp; 1\/2\" BSP Female Thread\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eFor 25mm (1\") ID Hose \u0026amp; 1\/2\" BSP Female Thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eAmps Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e13A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings reduce with head, hose length, bends and voltage drop.\u003c\/em\u003e\u003c\/p\u003e","brand":"Jabsco","offers":[{"title":"12v","offer_id":54832732275065,"sku":"ASAP-504434","price":250.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54832732307833,"sku":"ASAP-504432","price":250.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/23680_JPG.jpg?v=1695911681"},{"product_id":"johnson-pump-heavy-duty-bilge-4000gph","title":"Johnson Pump Heavy Duty Submersible Bilge Pump 4000GPH","description":"\u003cp\u003eThe best choice when you are looking for a high performance, heavy duty bilge pump that is designed to meet \u0026amp; exceed the tough demands of commercial \u0026amp; recreational duty.\u003c\/p\u003e\n\u003cp\u003eThis pump has a liquid cooled, 12-pole motor with double ball bearings for extended service life. The L2200 motor is sealed off by a mechanical seal that eliminates shaft wear \u0026amp; allows for service \u0026amp; replacement, while the L1600 has a lip seal.\u003c\/p\u003e\n\u003cp\u003eThe L4000 high capacity, heavy duty bilge pump has been developed by Johnson Pump as the premier pump in our submersible bilge pump range. Featuring a robust motor design, mechanical shaft seal, high impact ABS plastic and unique threaded port design, the L4000 will out perform all other comparable pumps on the market.\u003c\/p\u003e\n\u003cp\u003eUniversal base plate and a choice of 1.1\/2\" or 2\" ports makes for a simple installation.\u003c\/p\u003e\n\u003cp\u003eAll pumps include a removable check valve.\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-sheets-root=\"1\" data-sheets-baot=\"1\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"134\"\u003e\n\u003ccol width=\"145\"\u003e\n\u003ccol width=\"100\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eL4000\u003c\/td\u003e\n\u003ctd\u003eL4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eSS2343\u003c\/td\u003e\n\u003ctd\u003eSS2343\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e1.5mm²\u003c\/td\u003e\n\u003ctd\u003e1.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Diameter\u003c\/td\u003e\n\u003ctd\u003e121mm\u003c\/td\u003e\n\u003ctd\u003e121mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height\u003c\/td\u003e\n\u003ctd\u003e216mm\u003c\/td\u003e\n\u003ctd\u003e216mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.45kg\u003c\/td\u003e\n\u003ctd\u003e2.45kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Description\u003c\/td\u003e\n\u003ctd\u003e252 LPM (4000 GPH)\u003c\/td\u003e\n\u003ctd\u003e252 LPM (4000 GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Bilge Pumps\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eJohnson\u003c\/td\u003e\n\u003ctd\u003eJohnson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Description\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Johnson","offers":[{"title":"12v","offer_id":48444392997141,"sku":"AF-10-2240-01","price":249.95,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":57279502975353,"sku":"AF-10-2240-02","price":249.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/10-2240-02-1612420354.jpg?v=1695910475"},{"product_id":"lalizas-submersible-fully-automatic-bilge-pump-float-switch-600-gph-12v-la-31150","title":"Lalizas Submersible Fully Automatic Bilge Pump \u0026 Float Switch 600 GPH 12v","description":"\u003cp\u003eLalizas Submersible Fully Automatic Bilge Pump \u0026amp; Float Switch 600 GPH 12V.  Ref15:  LA-31150, \u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eConnections: Hosetail For 19mm (3\/4\") bore hose.\u003c\/li\u003e\n\t\u003cli\u003eDimensions: 90mm high, 145mm long, 82mm wide.\u003c\/li\u003e\n\t\u003cli\u003eFuse Size: 10 amp\u003c\/li\u003e\n\t\u003cli\u003eFully automated bilge pump with integral float switch.\u003c\/li\u003e\n\t\u003cli\u003eCompact pump for smaller vessels.\u003c\/li\u003e\n\t\u003cli\u003eTough ABS plastic body.\u003c\/li\u003e\n\t\u003cli\u003eQuick release inlet strainer allows rapid cleaning.\u003c\/li\u003e\n\t\u003cli\u003eManual Test Button\u003c\/li\u003e\n\t\u003cli\u003e12V DC 10A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lalizas","offers":[{"title":"Default Title","offer_id":47283820855573,"sku":"LA-31150","price":34.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/31150.jpg?v=1696258094"},{"product_id":"bilge-pump-1-5-38mm-hose-kit","title":"Bilge Pump  Hose Kit  - 1  1\/2\" \/ 38mm","description":"\u003cp\u003eBilge Pump Hose kit  - 1  1\/2\" \/ 38mm  \u003c\/p\u003e\n\n\u003cp\u003eContains:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e3 metres of 38mm internal diameter hose\u003c\/li\u003e\n\t\u003cli\u003e1 plastic skin fitting 38mm\u003c\/li\u003e\n\t\u003cli\u003e2 stainless steel hose clips (35mm-45mm)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Marine Scene","offers":[{"title":"Default Title","offer_id":47291978711317,"sku":"PUMPKIT38","price":28.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/bilge-20pump-20hose-20kitm.jpg?v=1698136714"},{"product_id":"clone-of-bilge-pump-hose-kit-3-4-19mm","title":"Bilge Pump  Hose kit  - 1 1\/8\" \/ 28mm","description":"\u003cp\u003eBilge Pump Hose Kit - 1 1\/8\" \/  28mm\u003c\/p\u003e\n\n\u003cp\u003eContains:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e3 metres of 28mm internal diameter hose \u003c\/li\u003e\n\t\u003cli\u003e1 plastic skin fitting 28mm       N109\u003c\/li\u003e\n\t\u003cli\u003e2 stainless steel hose clips (25mm-35mm)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Marine Scene","offers":[{"title":"Default Title","offer_id":47291979432213,"sku":"PUMPKIT28","price":25.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/bilge-20pump-20hose-20kitm_a6f56dc6-b491-4469-a887-cb10f403af82.jpg?v=1696412198"},{"product_id":"bilge-pump-1-hose-kit","title":"Bilge Pump  Hose Kit  - 1\" \/ 25.4mm","description":"\u003cp\u003eBilge Pump Hose Kit  - 1\" \/ 25.4mm \u003c\/p\u003e\n\n\u003cp\u003eContains:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e3 metres hose\u003c\/li\u003e\n\t\u003cli\u003e1 plastic skin fitting 25.4mm\u003c\/li\u003e\n\t\u003cli\u003e2 stainless steel hose clips (22mm-30mm)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Marine Scene","offers":[{"title":"Default Title","offer_id":47291980284181,"sku":"PUMPKIT25","price":25.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/bilge-20pump-20hose-20kitm_b2287f1a-72c5-49b8-afdc-ad99a1be7281.jpg?v=1698135943"},{"product_id":"bilge-pump-34mm-hose-kit","title":"Bilge Pump  Hose kit  - 3\/4\" \/ 19mm","description":"\u003cp\u003eBilge Pump Hose Kit - 3\/4\" \/ 19mm \u003c\/p\u003e\n\n\u003cp\u003eContains:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e3 metres hose\u003c\/li\u003e\n\t\u003cli\u003e1 plastic skin fitting 19mm     N42\u003c\/li\u003e\n\t\u003cli\u003e2 stainless steel hose clips (17mm-25mm)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Marine Scene","offers":[{"title":"Default Title","offer_id":47291981103381,"sku":"PUMPKIT19","price":23.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/bilge-20pump-20hose-20kitm_29d45858-c1dd-4ba5-85a0-2e5c18ca72a1.jpg?v=1698135549"},{"product_id":"clone-of-bilge-pump-1-5-38mm-hose-kit","title":"Bilge Pump Hose Kit -  1-1\/4\" \/ 32mm","description":"\u003cp\u003eBilge Pump 1-1\/4\" \/ 32mm Hose Kit\u003c\/p\u003e\n\n\u003cp\u003eContains:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e3 metres hose\u003c\/li\u003e\n\t\u003cli\u003e1 plastic skin fitting 32mm     N109\u003c\/li\u003e\n\t\u003cli\u003e2 stainless steel hose clips (25mm-35mm)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Marine Scene","offers":[{"title":"Default Title","offer_id":47291981955349,"sku":"PUMPKIT32","price":26.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/bilge-20pump-20hose-20kitm_61e51212-4d59-4c0b-bed3-cb54b659afcc.jpg?v=1700572937"},{"product_id":"premium-bilge-pump-suction-1-5-hose-kit-ms-premium-bphk-1-5","title":"Heavy Duty Bilge Pump Kit  1.5\" \/ 38mm","description":"\u003cp\u003eHeavy Duty Premium Bilge Pump Hose Kit with 1.5\" Internal Diameter Hose and Plastic Skin Fitting 32mm - 38mm        Ref19: MS-PREMIUM-BPHK-1.5\u003c\/p\u003e\n\n\u003cp\u003eKit Includes:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e1.5\" \/ 38mm  Int dia x 10 meters coil hose. (PD18)\u003c\/li\u003e\n\t\u003cli\u003e1 x Plastic Skin Fitting 32mm - 38mm\u003c\/li\u003e\n\t\u003cli\u003e4 x Stainless steel hose clips - 35mm-45mm. (SHOP \/ MA-HGS45RP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv\u003e\u003cstrong\u003e1.5\" dia x 10 metres coil hose: \u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv\u003eA quality delivery hose reinforced with a rigid internal crush and kink resistant white PVC helix. Optimum flow is maintained by the smooth bore.\u003c\/div\u003e\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eKey Features: \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\u003cul\u003e\n\t\u003cli\u003eTough, flexible and extremely durable\u003c\/li\u003e\n\t\u003cli\u003eRemains flexible, even in cold weather applications\u003c\/li\u003e\n\t\u003cli\u003eOutstanding resistance to the effects of weather\u003c\/li\u003e\n\t\u003cli\u003eExcellent chemical and abrasion resistance\u003c\/li\u003e\n\t\u003cli\u003eColour:  Green\u003c\/li\u003e\n\t\u003cli\u003eInternal Diameter:  38mm (1 1\/2\")\u003c\/li\u003e\n\t\u003cli\u003eExternal Diameter:  45mm\u003c\/li\u003e\n\t\u003cli\u003eWorking Pressure:  6.5 Bar\u003c\/li\u003e\n\t\u003cli\u003eVacuum H2O:  7\u003c\/li\u003e\n\t\u003cli\u003eBend Radius:  171mm\u003c\/li\u003e\n\t\u003cli\u003eWeight:  0.55kg\/m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Marine Scene","offers":[{"title":"Default Title","offer_id":47292017017109,"sku":"MS-PREMIUM-BPHK-1.5","price":60.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/HD-Hose.jpg?v=1696331336"},{"product_id":"quality-compact-bilge-pump-manual-cq-10-17050","title":"Compact Bilge Pump - Manual","description":"\u003cp\u003eQuality Compact Bilge Pump - 180mm x 125mm x 75mm\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eManual bilge pump made from non-corosive materials.\u003c\/li\u003e\n\t\u003cli\u003eBarbed inlet and outlet nozzles accomodate 25mm hoses.\u003c\/li\u003e\n\t\u003cli\u003eSurface or thru-deck mount, with a fixed handle.\u003c\/li\u003e\n\t\u003cli\u003eUp to 10 litres of water per 30 strokes in one minute.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"C-Quip","offers":[{"title":"Default Title","offer_id":47309806600469,"sku":"CQ-10-17050","price":39.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/10-17050.jpg?v=1741008051"},{"product_id":"rule-14a-16a-3700-series-submersible-bilge-pump-3700-gph","title":"Rule 14A \/ 16A 3700 Series Submersible Bilge Pump - 3700 GPH","description":"\u003cp\u003eThe Rule 3700 Series combines the 12V Rule 14A and 24V Rule 16A in one high-capacity submersible bilge-pump listing. Both models provide a nominal open-flow capacity of 3,700 GPH (14,010 LPH; approximately 233 litres per minute), use a 38 mm (1-1\/2 in) discharge connection and are supplied as non-automatic pumps for use with a separate, correctly rated control switch.\u003c\/p\u003e\n\u003cp\u003eDesigned for larger yachts, motor cruisers and workboats, the Rule 14A and 16A use a fully submersible centrifugal-pump design with a snap-lock strainer, stainless-steel shaft, blocked marine wiring, corrosion-resistant housing and built-in thermal cut-off. Select the model that matches the vessel's DC electrical system: Rule 14A for 12V installations or Rule 16A for 24V installations.\u003c\/p\u003e\n\u003ch4\u003eProduct Identification\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 3700 Series Submersible Bilge Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModels \/ part numbers:\u003c\/strong\u003e 14A and 16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKUs:\u003c\/strong\u003e CW-14A and CW-16A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Standard non-automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 3,700 GPH (14,010 LPH; approximately 233 litres per minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage options:\u003c\/strong\u003e 12V DC or 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 38 mm (1-1\/2 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump in the selected voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat Is the Rule 3700 Series Bilge Pump Used For?\u003c\/h4\u003e\n\u003cp\u003eThe Rule 3700 Series is used for high-capacity bilge drainage on larger yachts, motor cruisers and workboats. It removes nuisance water from the bilge through a fully submersible centrifugal pump and is intended for permanent marine installation.\u003c\/p\u003e\n\u003cp\u003eBoth models are non-automatic. For automatic operation, connect the pump to a suitably rated float switch, panel switch or other compatible control device.\u003c\/p\u003e\n\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOne Rule 3700 Series submersible bilge pump in the selected voltage\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFloat switch or control panel\u003c\/li\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eCable extensions and waterproof electrical connectors\u003c\/li\u003e\n\u003cli\u003eCircuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhich Variant Should I Choose?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRule 14A:\u003c\/strong\u003e Select this model for a 12V DC vessel electrical system. It draws 10.1A at 12V and uses a recommended 25A fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRule 16A:\u003c\/strong\u003e Select this model for a 24V DC vessel electrical system. It draws 6.9A at 24V and uses a recommended 15A fuse.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not connect a 12V pump to a 24V circuit or a 24V pump to a 12V circuit. Match the pump, switchgear, cable size and circuit protection to the vessel supply voltage and pump current.\u003c\/p\u003e\n\u003ch4\u003eIs a Separate Float Switch Required?\u003c\/h4\u003e\n\u003cp\u003eYes, if automatic operation is required. The Rule 14A and 16A are standard non-automatic pumps and must be controlled by a separate, suitably rated float switch, compatible panel switch or another appropriate control device.\u003c\/p\u003e\n\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\n\u003cp\u003eConfirm the complete installation rather than selecting by nominal capacity alone:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e Choose 14A for 12V DC or 16A for 24V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e Both models are rated at 3,700 GPH (14,010 LPH).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e Both models use 38 mm (1-1\/2 in) hose.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e Allow approximately 184 x 124 mm (H x W).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e Use the specified fuse for the selected model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge head:\u003c\/strong\u003e Both models are recommended for a maximum discharge head of 4 m.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\n\u003cp\u003eNo. The 3,700 GPH figure is a nominal open-flow rating. Actual output reduces as vertical discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/p\u003e\n\u003cp\u003eBoth models are rated at 2,900 GPH (10,977 LPH) at 1 m head and 2,450 GPH (9,274 LPH) at 2 m head. Keep the discharge route as short, direct and unrestricted as practical.\u003c\/p\u003e\n\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump type:\u003c\/strong\u003e Fully submersible centrifugal bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrainer:\u003c\/strong\u003e Snap-lock design for access to the impeller area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft:\u003c\/strong\u003e Stainless steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Blocked marine wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Corrosion-resistant construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 279\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e No integral non-return valve stated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE and ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\n\u003cp\u003eMount the pump at the lowest practical point of the bilge while retaining access for strainer cleaning and servicing. Connect it to 38 mm (1-1\/2 in) discharge hose and route the discharge to a correctly positioned outlet above the waterline.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse marine cable sized for the selected model's voltage, current and cable run.\u003c\/li\u003e\n\u003cli\u003eFit the recommended fuse close to the power source.\u003c\/li\u003e\n\u003cli\u003eKeep all electrical joints above the maximum anticipated bilge-water level.\u003c\/li\u003e\n\u003cli\u003eMinimise hose length, bends and restrictions.\u003c\/li\u003e\n\u003cli\u003eArrange the discharge system to reduce siphoning and backflow.\u003c\/li\u003e\n\u003cli\u003eUse switchgear rated for the pump load.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic control after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMaintenance\u003c\/h4\u003e\n\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or unreliable switching requires investigation before the vessel is used.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChoice of Rule 14A 12V or Rule 16A 24V model\u003c\/li\u003e\n\u003cli\u003eNominal open-flow capacity of 3,700 GPH (14,010 LPH)\u003c\/li\u003e\n\u003cli\u003eApproximately 233 litres per minute at nominal open flow\u003c\/li\u003e\n\u003cli\u003eHigh-capacity 38 mm (1-1\/2 in) discharge connection\u003c\/li\u003e\n\u003cli\u003eNon-automatic design for use with a separate control switch\u003c\/li\u003e\n\u003cli\u003eSnap-lock strainer for routine cleaning access\u003c\/li\u003e\n\u003cli\u003eStainless-steel shaft and blocked marine wiring\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eIgnition protected\u003c\/li\u003e\n\u003cli\u003eCE and ISO 8849 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the Rule 14A and Rule 16A?\u003c\/strong\u003e\u003cbr\u003eThe Rule 14A is the 12V model and the Rule 16A is the 24V model. Their nominal flow, dimensions, discharge size and flow-at-head ratings are the same, but their electrical current and recommended fuse ratings differ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this pump automatic?\u003c\/strong\u003e\u003cbr\u003eNo. Both variants are non-automatic and require a separate float switch, panel switch or other suitable control device for automatic operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich model should I use on a 12V boat?\u003c\/strong\u003e\u003cbr\u003eChoose the Rule 14A. The Rule 16A is designed for 24V systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill the pump deliver the full 3,700 GPH after installation?\u003c\/strong\u003e\u003cbr\u003eNot necessarily. The published capacity is an open-flow rating. Installed flow reduces as discharge head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the pump include a non-return valve?\u003c\/strong\u003e\u003cbr\u003eNo integral non-return valve is stated. Design the discharge system to control backflow and siphoning where required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this pump replace routine bilge inspection?\u003c\/strong\u003e\u003cbr\u003eNo. A bilge pump is one part of the vessel's water-management system. Inspect the bilge, pump, hose, wiring, discharge outlet and control switch regularly.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e14A\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e16A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-14A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3,700 GPH (14,010 LPH; approx. 233 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3,700 GPH (14,010 LPH; approx. 233 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - separate control switch required\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - separate control switch required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent at rated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e10.1A at 12V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e6.9A at 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent at charging voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12.2A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e10.0A at 27.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e25A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,900 GPH (10,977 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,900 GPH (10,977 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,450 GPH (9,274 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,450 GPH (9,274 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e184 x 124 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e184 x 124 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e38 mm (1-1\/2 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e38 mm (1-1\/2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e279\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e279\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo integral non-return valve stated\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo integral non-return valve stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eQuantity supplied\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eOne pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eOne pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"12v","offer_id":64695158571385,"sku":"ASAP-504122","price":377.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":64695237902713,"sku":"ASAP-504124","price":377.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/14A_jpg.jpg?v=1698135063"},{"product_id":"rule-24da-360-series-submersible-bilge-pump-1362-lph","title":"Rule 24DA 360 Series Submersible Bilge Pump - 1362 LPH","description":"\u003cp\u003eThe Rule 24DA is a non-automatic submersible bilge pump rated at 360 GPH (1,363 LPH; approx. 23 litres\/minute). It is designed for nuisance-water removal in small boats and compact bilge spaces, uses 19 mm (3\/4 in) discharge hose and requires a suitably rated float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003eThe Rule 24DA removes nuisance water from a boat bilge using a fully submersible centrifugal pump. The snap-lock strainer provides access to the impeller area for routine cleaning, while the stainless-steel shaft, blocked marine wiring, corrosion-resistant housing and built-in thermal cut-off are intended for permanent marine installation.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 24DA 360 Series Submersible Bilge Pump - 1362 LPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 24DA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e ASAP-JAB-24DA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Standard submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 360 GPH (1,363 LPH; approx. 23 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e No - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 2.1A at 12V; 2.4A at 13.6V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 24DA Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for nuisance-water removal in small boats and compact bilge spaces. It is a standard, non-automatic pump: power must be controlled by a separate Rule float switch, compatible panel switch or another correctly rated control device.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFloat switch or control panel\u003c\/li\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for nuisance-water removal in small boats and compact bilge spaces.\u003c\/li\u003e\n\u003cli\u003eConnect to 19 mm (3\/4 in) discharge hose and a correctly positioned above-waterline discharge outlet.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V.\u003c\/li\u003e\n\u003cli\u003eUse only with switching, cabling and circuit protection rated for the pump voltage and current.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIs a Separate Float Switch Required?\u003c\/h4\u003e\u003cp\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 360 GPH (1,363 LPH; approx. 23 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 99 x 74 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 265 GPH (1,003 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 190 GPH (719 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 1231R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while retaining access for strainer cleaning. Keep all electrical joints above the maximum anticipated bilge-water level, fit the manufacturer-specified fuse close to the power source, minimise hose length and bends, and route the discharge to prevent siphoning or backflow. Test both manual and automatic control after installation and during routine vessel checks.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 360 GPH (1,363 LPH; approx. 23 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eNon-automatic design for use with a separate switch\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer base and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eMarine-grade blocked wiring and stainless-steel shaft\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003cli\u003eCompact 360 GPH body\u003c\/li\u003e\n\u003cli\u003eVented housing and backflow prevention for 360-series installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eIs this Rule bilge pump automatic?\u003c\/strong\u003e\u003cbr\u003eNo. It is a standard pump and requires a separate float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage. Do not connect a 12V pump to a different-voltage circuit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the pump deliver the full rated output after installation?\u003c\/strong\u003e\u003cbr\u003eNot necessarily. The published rating is an open-flow figure; actual delivery falls as vertical head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this pump replace routine bilge inspection?\u003c\/strong\u003e\u003cbr\u003eNo. A bilge pump is one part of a vessel water-management system. Inspect the bilge, hoses, wiring, discharge outlet and switch regularly.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e24DA\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eASAP-JAB-24DA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e360 GPH (1,363 LPH; approx. 23 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2.1A at 12V; 2.4A at 13.6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e265 GPH (1,003 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e190 GPH (719 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e99 x 74 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm (3\/4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1231R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"Default Title","offer_id":47309866008853,"sku":"ASAP-JAB-24DA","price":32.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/s-l1600_5_ce475e7c-b126-4738-ac54-3f355b03f75f.jpg?v=1698135120"},{"product_id":"rule-27da-1100-series-submersible-bilge-pump-1100-gph","title":"Rule 27DA 1100 Series Submersible Bilge Pump - 1100 GPH","description":"\u003cp\u003eThe Rule 27DA \/ 27DA-24 is a non-automatic submersible bilge pump rated at 1,100 GPH (4,164 LPH; approx. 69 litres\/minute). It is designed for bilge-water removal in small and medium boats, uses 25 mm (1 in) or 29 mm (1-1\/8 in) discharge hose and requires a suitably rated float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003eThe Rule 27DA \/ 27DA-24 removes nuisance water from a boat bilge using a fully submersible centrifugal pump. The snap-lock strainer provides access to the impeller area for routine cleaning, while the stainless-steel shaft, blocked marine wiring, corrosion-resistant housing and built-in thermal cut-off are intended for permanent marine installation.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 27DA 1100 Series Submersible Bilge Pump - 1100 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 27DA \/ 27DA-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-27DA \/ CW-27DA-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Standard submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 1,100 GPH (4,164 LPH; approx. 69 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e No - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 25 mm (1 in) or 29 mm (1-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 3.7A at 12V; 4.7A at 13.6V \/ 1.9A at 24V; 2.2A at 27.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 7.5A \/ 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 27DA \/ 27DA-24 Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for bilge-water removal in small and medium boats. It is a standard, non-automatic pump: power must be controlled by a separate Rule float switch, compatible panel switch or another correctly rated control device.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFloat switch or control panel\u003c\/li\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for bilge-water removal in small and medium boats.\u003c\/li\u003e\n\u003cli\u003eConnect to 25 mm (1 in) or 29 mm (1-1\/8 in) discharge hose and a correctly positioned above-waterline discharge outlet.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V \/ 24V.\u003c\/li\u003e\n\u003cli\u003eUse only with switching, cabling and circuit protection rated for the pump voltage and current.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIs a Separate Float Switch Required?\u003c\/h4\u003e\u003cp\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/p\u003e\u003ch4\u003eWhich Voltage Should I Choose?\u003c\/h4\u003e\u003cp\u003eChoose the version that matches the vessel electrical system: 12V DC \/ 24V DC. A pump must only be connected to its stated DC supply voltage.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 1,100 GPH (4,164 LPH; approx. 69 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 25 mm (1 in) or 29 mm (1-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 111 x 74 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 7.5A \/ 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 860 GPH (3,255 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 550 GPH (2,081 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 1232R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while retaining access for strainer cleaning. Keep all electrical joints above the maximum anticipated bilge-water level, fit the manufacturer-specified fuse close to the power source, minimise hose length and bends, and route the discharge to prevent siphoning or backflow. Test both manual and automatic control after installation and during routine vessel checks.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 1,100 GPH (4,164 LPH; approx. 69 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eNon-automatic design for use with a separate switch\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer base and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eMarine-grade blocked wiring and stainless-steel shaft\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003cli\u003eBackflow prevention and vented impeller housing\u003c\/li\u003e\n\u003cli\u003e12V and 24V variants\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eIs this Rule bilge pump automatic?\u003c\/strong\u003e\u003cbr\u003eNo. It is a standard pump and requires a separate float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage. Do not connect a 12V \/ 24V pump to a different-voltage circuit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the pump deliver the full rated output after installation?\u003c\/strong\u003e\u003cbr\u003eNot necessarily. The published rating is an open-flow figure; actual delivery falls as vertical head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this pump replace routine bilge inspection?\u003c\/strong\u003e\u003cbr\u003eNo. A bilge pump is one part of a vessel water-management system. Inspect the bilge, hoses, wiring, discharge outlet and switch regularly.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e27DA\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e27DA-24\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-27DA\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-27DA-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,100 GPH (4,164 LPH; approx. 69 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,100 GPH (4,164 LPH; approx. 69 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3.7A at 12V; 4.7A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1.9A at 24V; 2.2A at 27.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e7.5A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e860 GPH (3,255 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e860 GPH (3,255 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e550 GPH (2,081 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e550 GPH (2,081 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e111 x 74 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e111 x 74 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e25 mm (1 in) or 29 mm (1-1\/8 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e25 mm (1 in) or 29 mm (1-1\/8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1232R\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1232R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"12v","offer_id":54837163688313,"sku":"ASAP-JAB-27DA","price":49.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54837163721081,"sku":"ASAP-JAB-27DA-24","price":68.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/27dapic.jpg?v=1698135212"},{"product_id":"rule-35a-rule-a-matic-compact-automatic-bilge-pump-float-switch","title":"Rule 35A Rule-A-Matic Compact Automatic Bilge Pump Float Switch","description":"\u003cp\u003eThe Rule 35A is a mercury-free bilge-pump float switch for automatic pump control on 12V and 24V DC systems, with a maximum switching capacity of 14A at 12V; 7A at 24V.\u003c\/p\u003e\u003cp\u003eThe Rule 35A controls a non-automatic bilge pump by closing the electrical circuit as water raises the float and opening the circuit after the water level falls. It uses marine-grade blocked wire and a mercury-free snap-switch design for marine bilge installations.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 35A Rule-A-Matic Compact Automatic Bilge Pump Float Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 35A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e ASAP-504793\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Automatic bilge-pump float switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible system voltage:\u003c\/strong\u003e 12V and 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum switched current:\u003c\/strong\u003e 14A at 12V; 7A at 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump ON level:\u003c\/strong\u003e Approx. 51 mm (2 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump OFF level:\u003c\/strong\u003e Approx. 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch mechanism:\u003c\/strong\u003e Mercury-free snap switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One float switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 35A Float Switch Used For?\u003c\/h4\u003e\u003cp\u003eThis switch is used to convert a compatible standard bilge pump into an automatically controlled system. It may also be used as the sensing switch in a compatible high-water alarm circuit where the electrical ratings and installation instructions are observed.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule 35A float switch\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade blocked wire\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBilge pump\u003c\/li\u003e\n\u003cli\u003ePanel switch\u003c\/li\u003e\n\u003cli\u003eCable extensions and waterproof connectors\u003c\/li\u003e\n\u003cli\u003eIn-line fuse holder and correctly rated fuse\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Bilge Pumps and Electrical Systems Are Compatible?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCompatible with 12V and 24V DC systems within the stated current limits.\u003c\/li\u003e\n\u003cli\u003eUse with a non-automatic bilge pump whose running and starting current do not exceed the switch rating.\u003c\/li\u003e\n\u003cli\u003eCan be combined with a compatible Rule three-way panel switch for automatic\/off\/manual control.\u003c\/li\u003e\n\u003cli\u003eNot a voltage converter; the pump, switch and panel must all suit the vessel electrical system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Do I Check the Electrical Rating?\u003c\/h4\u003e\u003cp\u003eThe pump operating and starting current must remain within the published switch rating: 14A at 12V; 7A at 24V. Match the switch, pump and any panel to the same system voltage: 12V and 24V DC.\u003c\/p\u003e\u003ch4\u003eAt What Water Level Does the Switch Operate?\u003c\/h4\u003e\u003cp\u003eThe published switching levels are ON at Approx. 51 mm (2 in) and OFF at Approx. 19 mm (3\/4 in). Installation angle, mounting position and unrestricted float movement must be maintained.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch mechanism:\u003c\/strong\u003e Mercury-free snap switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective cover:\u003c\/strong\u003e No external impact cover\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in test feature:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn-line fuse holder:\u003c\/strong\u003e Not included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting base:\u003c\/strong\u003e Removable, interchangeable mounting base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire size and length:\u003c\/strong\u003e 16 AWG marine-grade blocked wire; approx. 712 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the switch on a level surface beside the pump, with unrestricted float movement and without contact from hoses, wiring or debris. Position wiring connections above the maximum bilge-water level, fit the pump manufacturer’s specified fuse, and test the switch by lifting the float before leaving the vessel unattended. The fuse protects the circuit and must be selected for the pump; it is not set by the switch maximum-current rating.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eTest the switch through its full movement at regular intervals and keep the bilge area around it clear.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove oil, dirt and debris that could restrict the float.\u003c\/li\u003e\n\u003cli\u003eInspect the hinge, protective cover, wiring and terminals.\u003c\/li\u003e\n\u003cli\u003eConfirm that the pump starts and stops at the expected water levels.\u003c\/li\u003e\n\u003cli\u003eInvestigate repeated fuse failure or intermittent operation before relying on the automatic system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAutomatic on\/off control for compatible bilge pumps\u003c\/li\u003e\n\u003cli\u003eMercury-free snap-switch mechanism\u003c\/li\u003e\n\u003cli\u003eMarine-grade blocked wiring\u003c\/li\u003e\n\u003cli\u003eMaximum switching capacity: 14A at 12V; 7A at 24V\u003c\/li\u003e\n\u003cli\u003eIgnition protected for marine use\u003c\/li\u003e\n\u003cli\u003eCompact narrow profile\u003c\/li\u003e\n\u003cli\u003eRemovable base for cleaning and servicing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eWill this switch work with any bilge pump?\u003c\/strong\u003e\u003cbr\u003eOnly when the pump voltage and current are within the Rule 35A ratings. Check both running current and the manufacturer installation requirements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAt what water level does the switch operate?\u003c\/strong\u003e\u003cbr\u003eThe float switches on at approximately 51 mm (2 in) and switches off at approximately 19 mm (3\/4 in). Installation angle and bilge movement can affect actual operation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the maximum amp rating determine the fuse size?\u003c\/strong\u003e\u003cbr\u003eNo. Fit the fuse specified for the bilge pump and cable circuit. The switch rating is the maximum current the switch can control.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this product include a bilge pump?\u003c\/strong\u003e\u003cbr\u003eNo. This listing is for the float switch only.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e35A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eAutomatic bilge-pump float switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eASAP-504793\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCompatible system voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V and 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum switched current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e14A at 12V; 7A at 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003ePump ON level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eApprox. 51 mm (2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003ePump OFF level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eApprox. 19 mm (3\/4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eWire size and length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e16 AWG marine-grade blocked wire; approx. 712 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSwitch mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eMercury-free snap switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProtective cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo external impact cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBuilt-in test feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIn-line fuse holder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMounting base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRemovable, interchangeable mounting base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eApproximate dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e105 x 40 x 110 mm (L x W x maximum raised height)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eHigh-water alarm use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCompatible where circuit ratings and installation requirements are met\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Rule","offers":[{"title":"Default Title","offer_id":47309867319573,"sku":"ASAP-504793","price":44.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/61Ex8jsFf-S._AC_SL1176.jpg?v=1698136593"},{"product_id":"rule-53s-2000-series-automatic-submersible-bilge-pump-2000-gph","title":"Rule 53S 2000 Series Automatic Submersible Bilge Pump - 2000 GPH","description":"\u003cp\u003eThe Rule 53S is an automatic submersible bilge pump rated at 2,000 GPH (7,571 LPH; approx. 126 litres\/minute). It checks for water every 2.5 minutes and runs when resistance at the impeller indicates water is present, so no separate float switch is required.\u003c\/p\u003e\u003cp\u003eThe Rule 53S combines a fully submersible centrifugal bilge pump with integral automatic control. During normal operation the pump briefly checks for water at 2.5-minute intervals and continues running when water is detected. This eliminates the need for a separate float switch while retaining a compact installation footprint.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 53S 2000 Series Automatic Submersible Bilge Pump - 2000 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 53S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-53S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 2,000 GPH (7,571 LPH; approx. 126 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e Yes - integral timed water-sensing operation; no separate float switch required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 29 mm (1-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 8.4A at 12V; 12.0A at 13.6V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 53S Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for automatic removal of nuisance water from medium-sized yachts and motor cruisers. It is intended for permanent marine installation and should be selected by required flow, supply voltage, discharge-hose size and expected discharge head.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral timed water-sensing control\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eOptional panel switch\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for medium-sized yachts and motor cruisers.\u003c\/li\u003e\n\u003cli\u003eConnect to 29 mm (1-1\/8 in) discharge hose.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V.\u003c\/li\u003e\n\u003cli\u003eA compatible Rule panel switch may be fitted where manual override or status control is required.\u003c\/li\u003e\n\u003cli\u003eNo separate external float switch is needed for automatic operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Does the Automatic Operation Work?\u003c\/h4\u003e\u003cp\u003eYes - integral timed water-sensing operation; no separate float switch required The published automatic check cycle is pump checks for water every 2.5 minutes. Separate float switch required: No.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 2,000 GPH (7,571 LPH; approx. 126 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 29 mm (1-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 197 x 121 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 1,620 GPH (6,132 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 1,300 GPH (4,921 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 278\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e No integral non-return valve stated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while maintaining access for cleaning. Wire directly through the specified fuse and follow the manufacturer wiring diagram for any manual-override lead. Keep electrical joints above the maximum bilge-water level, minimise hose length and bends, prevent siphoning, and test automatic operation before leaving the vessel unattended.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eKeep the automatic sensor or float-switch movement clear of oil, dirt and debris.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 2,000 GPH (7,571 LPH; approx. 126 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eIntegral automatic water checking every 2.5 minutes\u003c\/li\u003e\n\u003cli\u003eNo separate float switch required\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eDoes this automatic pump need a float switch?\u003c\/strong\u003e\u003cbr\u003eNo. The automatic control is built into the pump.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy does the pump run briefly when the bilge appears dry?\u003c\/strong\u003e\u003cbr\u003eThe pump checks for water at 2.5-minute intervals. It stops after the short check when no water resistance is detected.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage: 12V. Also confirm the hose size, fuse rating and available installation space.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the stated flow equal the installed flow?\u003c\/strong\u003e\u003cbr\u003eThe stated capacity is an open-flow rating. Actual output falls as discharge head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e53S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eAutomatic submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-53S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,000 GPH (7,571 LPH; approx. 126 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes - integral timed water-sensing operation; no separate float switch required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e8.4A at 12V; 12.0A at 13.6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,620 GPH (6,132 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,300 GPH (4,921 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e197 x 121 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e29 mm (1-1\/8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo integral non-return valve stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic check cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003ePump checks for water every 2.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSeparate float switch required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"Default Title","offer_id":47309867843861,"sku":"ASAP-504116","price":274.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/53s.jpg?v=1698135942"},{"product_id":"rule-automatic-computerised-bilge-pump-500-gph-12v-cw-25sa","title":"Rule 25SA 500 Series Automatic Submersible Bilge Pump - 500 GPH","description":"\u003cp\u003eThe Rule 25SA \/ 25SA-24 is an automatic submersible bilge pump rated at 500 GPH (1,893 LPH; approx. 32 litres\/minute). It checks for water every 2.5 minutes and runs when resistance at the impeller indicates water is present, so no separate float switch is required.\u003c\/p\u003e\u003cp\u003eThe Rule 25SA \/ 25SA-24 combines a fully submersible centrifugal bilge pump with integral automatic control. During normal operation the pump briefly checks for water at 2.5-minute intervals and continues running when water is detected. This eliminates the need for a separate float switch while retaining a compact installation footprint.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 25SA 500 Series Automatic Submersible Bilge Pump - 500 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 25SA \/ 25SA-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-25SA \/ CW-25SA-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 500 GPH (1,893 LPH; approx. 32 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e Yes - integral timed water-sensing operation; no separate float switch required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 2.1A at 12V; 2.4A at 13.6V \/ 1.0A at 24V; 1.2A at 27.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 4A \/ 3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 25SA \/ 25SA-24 Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for automatic removal of nuisance water from small craft and compact bilge spaces. It is intended for permanent marine installation and should be selected by required flow, supply voltage, discharge-hose size and expected discharge head.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral timed water-sensing control\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eOptional panel switch\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for small craft and compact bilge spaces.\u003c\/li\u003e\n\u003cli\u003eConnect to 19 mm (3\/4 in) discharge hose.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V \/ 24V.\u003c\/li\u003e\n\u003cli\u003eA compatible Rule panel switch may be fitted where manual override or status control is required.\u003c\/li\u003e\n\u003cli\u003eNo separate external float switch is needed for automatic operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Does the Automatic Operation Work?\u003c\/h4\u003e\u003cp\u003eYes - integral timed water-sensing operation; no separate float switch required The published automatic check cycle is pump checks for water every 2.5 minutes. Separate float switch required: No.\u003c\/p\u003e\u003ch4\u003eWhich Voltage Should I Choose?\u003c\/h4\u003e\u003cp\u003eChoose the version that matches the vessel electrical system: 12V DC \/ 24V DC. A pump must only be connected to its stated DC supply voltage.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 500 GPH (1,893 LPH; approx. 32 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 107 x 74 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 4A \/ 3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 360 GPH (1,362 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 260 GPH (984 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 1231R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while maintaining access for cleaning. Wire directly through the specified fuse and follow the manufacturer wiring diagram for any manual-override lead. Keep electrical joints above the maximum bilge-water level, minimise hose length and bends, prevent siphoning, and test automatic operation before leaving the vessel unattended.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eKeep the automatic sensor or float-switch movement clear of oil, dirt and debris.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 500 GPH (1,893 LPH; approx. 32 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eIntegral automatic water checking every 2.5 minutes\u003c\/li\u003e\n\u003cli\u003eNo separate float switch required\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eDoes this automatic pump need a float switch?\u003c\/strong\u003e\u003cbr\u003eNo. The automatic control is built into the pump.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy does the pump run briefly when the bilge appears dry?\u003c\/strong\u003e\u003cbr\u003eThe pump checks for water at 2.5-minute intervals. It stops after the short check when no water resistance is detected.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage: 12V \/ 24V. Also confirm the hose size, fuse rating and available installation space.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the stated flow equal the installed flow?\u003c\/strong\u003e\u003cbr\u003eThe stated capacity is an open-flow rating. Actual output falls as discharge head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e25SA\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e25SA-24\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eAutomatic submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eAutomatic submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-25SA\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-25SA-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e500 GPH (1,893 LPH; approx. 32 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e500 GPH (1,893 LPH; approx. 32 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes - integral timed water-sensing operation; no separate float switch required\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes - integral timed water-sensing operation; no separate float switch required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2.1A at 12V; 2.4A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1.0A at 24V; 1.2A at 27.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e360 GPH (1,362 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e360 GPH (1,362 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e260 GPH (984 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e260 GPH (984 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e107 x 74 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e107 x 74 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm (3\/4 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm (3\/4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1231R\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1231R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic check cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003ePump checks for water every 2.5 minutes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003ePump checks for water every 2.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSeparate float switch required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"12v","offer_id":54837063549305,"sku":"ASAP-JAB-25SA","price":101.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54837063582073,"sku":"ASAP-JAB-25SA-24","price":122.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/25sa-20pic1.jpg?v=1700569808"},{"product_id":"rule-55s-3700-series-automatic-submersible-bilge-pump-3700-gph","title":"Rule 55S 3700 Series Automatic Submersible Bilge Pump - 3700 GPH","description":"\u003cp\u003eThe Rule 55S is an automatic submersible bilge pump rated at 3,700 GPH (14,010 LPH; approx. 233 litres\/minute). It checks for water every 2.5 minutes and runs when resistance at the impeller indicates water is present, so no separate float switch is required.\u003c\/p\u003e\u003cp\u003eThe Rule 55S combines a fully submersible centrifugal bilge pump with integral automatic control. During normal operation the pump briefly checks for water at 2.5-minute intervals and continues running when water is detected. This eliminates the need for a separate float switch while retaining a compact installation footprint.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 55S 3700 Series Automatic Submersible Bilge Pump - 3700 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 55S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-55S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 3,700 GPH (14,010 LPH; approx. 233 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e Yes - integral timed water-sensing operation; no separate float switch required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 38 mm (1-1\/2 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 15.5A at 12V; 20.0A at 13.6V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 55S Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for automatic removal of nuisance water from larger yachts, motor cruisers and high-capacity bilge installations. It is intended for permanent marine installation and should be selected by required flow, supply voltage, discharge-hose size and expected discharge head.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral timed water-sensing control\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eOptional panel switch\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for larger yachts, motor cruisers and high-capacity bilge installations.\u003c\/li\u003e\n\u003cli\u003eConnect to 38 mm (1-1\/2 in) discharge hose.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V.\u003c\/li\u003e\n\u003cli\u003eA compatible Rule panel switch may be fitted where manual override or status control is required.\u003c\/li\u003e\n\u003cli\u003eNo separate external float switch is needed for automatic operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Does the Automatic Operation Work?\u003c\/h4\u003e\u003cp\u003eYes - integral timed water-sensing operation; no separate float switch required The published automatic check cycle is pump checks for water every 2.5 minutes. Separate float switch required: No.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 3,700 GPH (14,010 LPH; approx. 233 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 38 mm (1-1\/2 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 209 x 124 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 2,900 GPH (10,977 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 2,450 GPH (9,274 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 279\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e No integral non-return valve stated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while maintaining access for cleaning. Wire directly through the specified fuse and follow the manufacturer wiring diagram for any manual-override lead. Keep electrical joints above the maximum bilge-water level, minimise hose length and bends, prevent siphoning, and test automatic operation before leaving the vessel unattended.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eKeep the automatic sensor or float-switch movement clear of oil, dirt and debris.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 3,700 GPH (14,010 LPH; approx. 233 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eIntegral automatic water checking every 2.5 minutes\u003c\/li\u003e\n\u003cli\u003eNo separate float switch required\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eDoes this automatic pump need a float switch?\u003c\/strong\u003e\u003cbr\u003eNo. The automatic control is built into the pump.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy does the pump run briefly when the bilge appears dry?\u003c\/strong\u003e\u003cbr\u003eThe pump checks for water at 2.5-minute intervals. It stops after the short check when no water resistance is detected.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage: 12V. Also confirm the hose size, fuse rating and available installation space.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the stated flow equal the installed flow?\u003c\/strong\u003e\u003cbr\u003eThe stated capacity is an open-flow rating. Actual output falls as discharge head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e55S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eAutomatic submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-55S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3,700 GPH (14,010 LPH; approx. 233 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes - integral timed water-sensing operation; no separate float switch required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e15.5A at 12V; 20.0A at 13.6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,900 GPH (10,977 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,450 GPH (9,274 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e209 x 124 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e38 mm (1-1\/2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e279\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo integral non-return valve stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic check cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003ePump checks for water every 2.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSeparate float switch required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"Default Title","offer_id":47309870432533,"sku":"ASAP-JAB-55S","price":379.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/55s.jpg?v=1698136128"},{"product_id":"rule-02-03-1500-series-submersible-bilge-pump-1500-gph","title":"Rule 02 \/ 03 1500 Series Submersible Bilge Pump - 1500 GPH","description":"\u003cp\u003eThe Rule 02 \/ 03 is a non-automatic submersible bilge pump rated at 1,500 GPH (5,678 LPH; approx. 95 litres\/minute). It is designed for medium-capacity bilge drainage on yachts and motor cruisers, uses 29 mm (1-1\/8 in) discharge hose and requires a suitably rated float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003eThe Rule 02 \/ 03 removes nuisance water from a boat bilge using a fully submersible centrifugal pump. The snap-lock strainer provides access to the impeller area for routine cleaning, while the stainless-steel shaft, blocked marine wiring, corrosion-resistant housing and built-in thermal cut-off are intended for permanent marine installation.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 02 \/ 03 1500 Series Submersible Bilge Pump - 1500 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 02 \/ 03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-02 \/ CW-03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Standard submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 1,500 GPH (5,678 LPH; approx. 95 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e No - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 29 mm (1-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 4.0A at 12V; 4.8A at 13.6V \/ 2.3A at 24V; 3.5A at 27.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 10A \/ 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 02 \/ 03 Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for medium-capacity bilge drainage on yachts and motor cruisers. It is a standard, non-automatic pump: power must be controlled by a separate Rule float switch, compatible panel switch or another correctly rated control device.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFloat switch or control panel\u003c\/li\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for medium-capacity bilge drainage on yachts and motor cruisers.\u003c\/li\u003e\n\u003cli\u003eConnect to 29 mm (1-1\/8 in) discharge hose and a correctly positioned above-waterline discharge outlet.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V \/ 24V.\u003c\/li\u003e\n\u003cli\u003eUse only with switching, cabling and circuit protection rated for the pump voltage and current.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIs a Separate Float Switch Required?\u003c\/h4\u003e\u003cp\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/p\u003e\u003ch4\u003eWhich Voltage Should I Choose?\u003c\/h4\u003e\u003cp\u003eChoose the version that matches the vessel electrical system: 12V DC \/ 24V DC. A pump must only be connected to its stated DC supply voltage.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 1,500 GPH (5,678 LPH; approx. 95 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 29 mm (1-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 152 x 108 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 10A \/ 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 1,200 GPH (4,542 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 680 GPH (2,574 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 278\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e No integral non-return valve stated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while retaining access for strainer cleaning. Keep all electrical joints above the maximum anticipated bilge-water level, fit the manufacturer-specified fuse close to the power source, minimise hose length and bends, and route the discharge to prevent siphoning or backflow. Test both manual and automatic control after installation and during routine vessel checks.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 1,500 GPH (5,678 LPH; approx. 95 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eNon-automatic design for use with a separate switch\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer base and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eMarine-grade blocked wiring and stainless-steel shaft\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003cli\u003e12V model 02 and 24V model 03 options\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eIs this Rule bilge pump automatic?\u003c\/strong\u003e\u003cbr\u003eNo. It is a standard pump and requires a separate float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage. Do not connect a 12V \/ 24V pump to a different-voltage circuit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the pump deliver the full rated output after installation?\u003c\/strong\u003e\u003cbr\u003eNot necessarily. The published rating is an open-flow figure; actual delivery falls as vertical head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this pump replace routine bilge inspection?\u003c\/strong\u003e\u003cbr\u003eNo. A bilge pump is one part of a vessel water-management system. Inspect the bilge, hoses, wiring, discharge outlet and switch regularly.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e02\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e03\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-02\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,500 GPH (5,678 LPH; approx. 95 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,500 GPH (5,678 LPH; approx. 95 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4.0A at 12V; 4.8A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2.3A at 24V; 3.5A at 27.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e10A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,200 GPH (4,542 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,200 GPH (4,542 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e680 GPH (2,574 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e680 GPH (2,574 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e152 x 108 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e152 x 108 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e29 mm (1-1\/8 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e29 mm (1-1\/8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e278\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo integral non-return valve stated\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo integral non-return valve stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"12v","offer_id":54914387575161,"sku":"ASAP-504102","price":194.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54914387607929,"sku":"ASAP-504104","price":194.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/049530z.jpg?v=1700571748"},{"product_id":"rule-24da-360-series-submersible-bilge-pump-with-35a-float-switch-1362-lph","title":"Rule 24DA 360 Series Submersible Bilge Pump With 35A Float Switch - 1362 LPH","description":"\u003cp\u003eThis Rule kit combines a 12V 24DA 360 GPH submersible bilge pump with a 35A Rule-A-Matic float switch, providing automatic bilge-water removal when correctly wired and fused.\u003c\/p\u003e\u003cp\u003eThe kit pairs Rule’s compact 24DA standard bilge pump with the Rule 35A mercury-free float switch. The pump itself is non-automatic; the 35A switch closes the circuit as the water level rises and opens it after the water level falls, creating a conventional automatic bilge-pump system.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 24DA 360 Series Submersible Bilge Pump With 35A Float Switch - 1362 LPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 24DA pump + 35A float switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e ASAP-JAB-24DA-35A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Standard submersible bilge pump \/ Bilge-pump float switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 360 GPH (1,363 LPH; approx. 23 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem voltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic control:\u003c\/strong\u003e Yes - via the included Rule 35A float switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump current draw:\u003c\/strong\u003e 2.1A at 12V; 2.4A at 13.6V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended pump fuse:\u003c\/strong\u003e 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump and one float switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 24DA and 35A Bilge Pump Kit Used For?\u003c\/h4\u003e\u003cp\u003eThis kit is used to install an automatic 12V bilge-pumping system in smaller craft and confined bilge spaces. The 360 GPH pump removes nuisance water, while the float switch provides automatic on\/off control.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule 24DA 360 GPH submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eOne Rule 35A Rule-A-Matic float switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003ePanel switch\u003c\/li\u003e\n\u003cli\u003eCorrectly rated fuse, cable extensions and waterproof connectors\u003c\/li\u003e\n\u003cli\u003eInstallation fasteners unless present in the retail package\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Kit Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFor 12V DC marine electrical systems.\u003c\/li\u003e\n\u003cli\u003ePump connects to 19 mm (3\/4 in) ID discharge hose.\u003c\/li\u003e\n\u003cli\u003e35A switch is rated up to 14A at 12V; the included 24DA pump draws substantially less than this limit.\u003c\/li\u003e\n\u003cli\u003eSuitable for conventional automatic control; an optional 12V three-way panel switch may be added for automatic\/off\/manual control.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Do the Pump and Float Switch Work Together?\u003c\/h4\u003e\u003cp\u003eThe 24DA pump provides the water-removal flow, while the 35A float switch opens and closes the pump circuit as the bilge-water level rises and falls. The pump is not independently automatic; automatic operation depends on correct float-switch installation and wiring.\u003c\/p\u003e\u003ch4\u003eHow Do I Confirm This Kit Is Suitable?\u003c\/h4\u003e\u003cp\u003eCheck the electrical system, available bilge space, discharge route and switching capacity before installation:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem voltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump rated open flow:\u003c\/strong\u003e 360 GPH (1,363 LPH; approx. 23 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat-switch maximum current:\u003c\/strong\u003e 14A at 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump ON level:\u003c\/strong\u003e Approx. 51 mm (2 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump OFF level:\u003c\/strong\u003e Approx. 19 mm (3\/4 in)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting base:\u003c\/strong\u003e Removable for cleaning and servicing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge and install the float switch nearby on a level surface where it can move freely. The pump and switch must be wired through the specified fuse using marine-grade cable and waterproof connections positioned above the maximum bilge-water level. Test switch movement and pump operation after installation and at regular service intervals.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eKeep the automatic sensor or float-switch movement clear of oil, dirt and debris.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eComplete pump-and-float-switch combination for automatic operation\u003c\/li\u003e\n\u003cli\u003e360 GPH (1,363 LPH) nominal open-flow pump capacity\u003c\/li\u003e\n\u003cli\u003e12V DC operation\u003c\/li\u003e\n\u003cli\u003e19 mm (3\/4 in) discharge connection\u003c\/li\u003e\n\u003cli\u003ePump includes thermal cut-off and easy-clean strainer\u003c\/li\u003e\n\u003cli\u003e35A switch is mercury-free, ignition protected and serviceable from its removable base\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eIs the Rule 24DA pump automatic by itself?\u003c\/strong\u003e\u003cbr\u003eNo. Automatic control is provided by wiring the included Rule 35A float switch into the pump circuit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat hose size is required?\u003c\/strong\u003e\u003cbr\u003eUse 19 mm (3\/4 in) ID bilge hose and secure it with suitable marine-grade hose clips.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the kit include a panel switch?\u003c\/strong\u003e\u003cbr\u003eNo. A compatible 12V panel switch can be added separately where manual override is required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat fuse should be used?\u003c\/strong\u003e\u003cbr\u003eUse the pump manufacturer’s recommended 4A fuse and follow the installation diagram. The float switch rating is a maximum switching capacity, not the required fuse size.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e24DA\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e35A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBilge-pump float switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eASAP-JAB-24DA\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e360 GPH (1,363 LPH; approx. 23 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2.1A at 12V; 2.4A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e265 GPH (1,003 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e190 GPH (719 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e99 x 74 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm (3\/4 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1231R\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eKit SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eASAP-JAB-24DA-35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSystem voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum switched current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e14A at 12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003ePump ON level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eApprox. 51 mm (2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003ePump OFF level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eApprox. 19 mm (3\/4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eWire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e16 AWG marine-grade blocked wire; approx. 712 mm long\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSwitch type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eMercury-free snap switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMounting base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRemovable for cleaning and servicing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"Default Title","offer_id":47309871677717,"sku":"ASAP-JAB-24DA-35A","price":81.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/24da-35a_jpg.jpg?v=1698135288"},{"product_id":"rule-25da-500-series-submersible-bilge-pump-500-gph","title":"Rule 25DA 500 Series Submersible Bilge Pump - 500 GPH","description":"\u003cp\u003eThe Rule 25DA \/ 25DA-24 is a non-automatic submersible bilge pump rated at 500 GPH (1,893 LPH; approx. 32 litres\/minute). It is designed for nuisance-water removal in small craft and compact bilges, uses 19 mm (3\/4 in) discharge hose and requires a suitably rated float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003eThe Rule 25DA \/ 25DA-24 removes nuisance water from a boat bilge using a fully submersible centrifugal pump. The snap-lock strainer provides access to the impeller area for routine cleaning, while the stainless-steel shaft, blocked marine wiring, corrosion-resistant housing and built-in thermal cut-off are intended for permanent marine installation.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 25DA 500 Series Submersible Bilge Pump - 500 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 25DA \/ 25DA-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-25DA \/ CW-25DA-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Standard submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 500 GPH (1,893 LPH; approx. 32 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e No - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 1.6A at 12V; 1.8A at 13.6V \/ 1.0A at 24V; 1.2A at 27.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 4A \/ 3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 25DA \/ 25DA-24 Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for nuisance-water removal in small craft and compact bilges. It is a standard, non-automatic pump: power must be controlled by a separate Rule float switch, compatible panel switch or another correctly rated control device.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFloat switch or control panel\u003c\/li\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for nuisance-water removal in small craft and compact bilges.\u003c\/li\u003e\n\u003cli\u003eConnect to 19 mm (3\/4 in) discharge hose and a correctly positioned above-waterline discharge outlet.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V \/ 24V.\u003c\/li\u003e\n\u003cli\u003eUse only with switching, cabling and circuit protection rated for the pump voltage and current.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIs a Separate Float Switch Required?\u003c\/h4\u003e\u003cp\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/p\u003e\u003ch4\u003eWhich Voltage Should I Choose?\u003c\/h4\u003e\u003cp\u003eChoose the version that matches the vessel electrical system: 12V DC \/ 24V DC. A pump must only be connected to its stated DC supply voltage.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 500 GPH (1,893 LPH; approx. 32 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 99 x 74 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 4A \/ 3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 360 GPH (1,362 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 260 GPH (984 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 1231R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while retaining access for strainer cleaning. Keep all electrical joints above the maximum anticipated bilge-water level, fit the manufacturer-specified fuse close to the power source, minimise hose length and bends, and route the discharge to prevent siphoning or backflow. Test both manual and automatic control after installation and during routine vessel checks.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 500 GPH (1,893 LPH; approx. 32 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eNon-automatic design for use with a separate switch\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer base and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eMarine-grade blocked wiring and stainless-steel shaft\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003cli\u003eBackflow prevention and vented impeller housing\u003c\/li\u003e\n\u003cli\u003e12V and 24V variants\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eIs this Rule bilge pump automatic?\u003c\/strong\u003e\u003cbr\u003eNo. It is a standard pump and requires a separate float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage. Do not connect a 12V \/ 24V pump to a different-voltage circuit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the pump deliver the full rated output after installation?\u003c\/strong\u003e\u003cbr\u003eNot necessarily. The published rating is an open-flow figure; actual delivery falls as vertical head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this pump replace routine bilge inspection?\u003c\/strong\u003e\u003cbr\u003eNo. A bilge pump is one part of a vessel water-management system. Inspect the bilge, hoses, wiring, discharge outlet and switch regularly.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e25DA\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e25DA-24\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-25DA\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-25DA-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e500 GPH (1,893 LPH; approx. 32 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e500 GPH (1,893 LPH; approx. 32 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1.6A at 12V; 1.8A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1.0A at 24V; 1.2A at 27.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e360 GPH (1,362 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e360 GPH (1,362 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e260 GPH (984 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e260 GPH (984 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e99 x 74 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e99 x 74 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm (3\/4 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm (3\/4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1231R\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1231R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"12v","offer_id":54837134623097,"sku":"ASAP-JAB-25DA","price":40.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54837134655865,"sku":"ASAP-JAB-25DA-24","price":45.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/25dapic-20.jpg?v=1698135648"},{"product_id":"rule-computerised-automatic-bilge-pump-1100-gph-12v-cw-27sa","title":"Rule 27SA 1100 Series Automatic Submersible Bilge Pump - 1100 GPH","description":"\u003cp\u003eThe Rule 27SA \/ 27SA-24 is an automatic submersible bilge pump rated at 1,100 GPH (4,164 LPH; approx. 69 litres\/minute). It checks for water every 2.5 minutes and runs when resistance at the impeller indicates water is present, so no separate float switch is required.\u003c\/p\u003e\u003cp\u003eThe Rule 27SA \/ 27SA-24 combines a fully submersible centrifugal bilge pump with integral automatic control. During normal operation the pump briefly checks for water at 2.5-minute intervals and continues running when water is detected. This eliminates the need for a separate float switch while retaining a compact installation footprint.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 27SA 1100 Series Automatic Submersible Bilge Pump - 1100 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 27SA \/ 27SA-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-27SA \/ CW-27SA-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 1,100 GPH (4,164 LPH; approx. 69 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e Yes - integral timed water-sensing operation; no separate float switch required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 25 mm (1 in) or 29 mm (1-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 3.7A at 12V; 4.7A at 13.6V \/ 1.9A at 24V; 2.2A at 27.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 7.5A \/ 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 27SA \/ 27SA-24 Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for automatic removal of nuisance water from small and medium boats. It is intended for permanent marine installation and should be selected by required flow, supply voltage, discharge-hose size and expected discharge head.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral timed water-sensing control\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eOptional panel switch\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for small and medium boats.\u003c\/li\u003e\n\u003cli\u003eConnect to 25 mm (1 in) or 29 mm (1-1\/8 in) discharge hose.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V \/ 24V.\u003c\/li\u003e\n\u003cli\u003eA compatible Rule panel switch may be fitted where manual override or status control is required.\u003c\/li\u003e\n\u003cli\u003eNo separate external float switch is needed for automatic operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Does the Automatic Operation Work?\u003c\/h4\u003e\u003cp\u003eYes - integral timed water-sensing operation; no separate float switch required The published automatic check cycle is pump checks for water every 2.5 minutes. Separate float switch required: No.\u003c\/p\u003e\u003ch4\u003eWhich Voltage Should I Choose?\u003c\/h4\u003e\u003cp\u003eChoose the version that matches the vessel electrical system: 12V DC \/ 24V DC. A pump must only be connected to its stated DC supply voltage.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 1,100 GPH (4,164 LPH; approx. 69 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 25 mm (1 in) or 29 mm (1-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 120 x 74 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 7.5A \/ 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 860 GPH (3,255 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 550 GPH (2,081 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 1232R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while maintaining access for cleaning. Wire directly through the specified fuse and follow the manufacturer wiring diagram for any manual-override lead. Keep electrical joints above the maximum bilge-water level, minimise hose length and bends, prevent siphoning, and test automatic operation before leaving the vessel unattended.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eKeep the automatic sensor or float-switch movement clear of oil, dirt and debris.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 1,100 GPH (4,164 LPH; approx. 69 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eIntegral automatic water checking every 2.5 minutes\u003c\/li\u003e\n\u003cli\u003eNo separate float switch required\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eDoes this automatic pump need a float switch?\u003c\/strong\u003e\u003cbr\u003eNo. The automatic control is built into the pump.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy does the pump run briefly when the bilge appears dry?\u003c\/strong\u003e\u003cbr\u003eThe pump checks for water at 2.5-minute intervals. It stops after the short check when no water resistance is detected.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage: 12V \/ 24V. Also confirm the hose size, fuse rating and available installation space.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the stated flow equal the installed flow?\u003c\/strong\u003e\u003cbr\u003eThe stated capacity is an open-flow rating. Actual output falls as discharge head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e27SA\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e27SA-24\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eAutomatic submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eAutomatic submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-27SA\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-27SA-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,100 GPH (4,164 LPH; approx. 69 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,100 GPH (4,164 LPH; approx. 69 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes - integral timed water-sensing operation; no separate float switch required\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes - integral timed water-sensing operation; no separate float switch required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3.7A at 12V; 4.7A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1.9A at 24V; 2.2A at 27.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e7.5A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e860 GPH (3,255 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e860 GPH (3,255 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e550 GPH (2,081 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e550 GPH (2,081 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e120 x 74 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e120 x 74 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e25 mm (1 in) or 29 mm (1-1\/8 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e25 mm (1 in) or 29 mm (1-1\/8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1232R\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1232R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic check cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003ePump checks for water every 2.5 minutes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003ePump checks for water every 2.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSeparate float switch required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"12v","offer_id":54837197799801,"sku":"ASAP-JAB-27SA","price":149.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54837197832569,"sku":"CW-27SA-24","price":154.95,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/Rule-500-Computerised-Auto-Bilge-Pump-12V.jpg?v=1696422692"},{"product_id":"rule-automatic-computerised-bilge-pump-800-gph-12v-cw-20sa","title":"Rule 20SA 800 Series Automatic Submersible Bilge Pump - 800 GPH","description":"\u003cp\u003eThe Rule 20SA is an automatic submersible bilge pump rated at 800 GPH (3,028 LPH; approx. 50 litres\/minute). It checks for water every 2.5 minutes and runs when resistance at the impeller indicates water is present, so no separate float switch is required.\u003c\/p\u003e\u003cp\u003eThe Rule 20SA combines a fully submersible centrifugal bilge pump with integral automatic control. During normal operation the pump briefly checks for water at 2.5-minute intervals and continues running when water is detected. This eliminates the need for a separate float switch while retaining a compact installation footprint.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 20SA 800 Series Automatic Submersible Bilge Pump - 800 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 20SA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-20SA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 800 GPH (3,028 LPH; approx. 50 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e Yes - integral timed water-sensing operation; no separate float switch required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 3.4A at 12V; 4.3A at 13.6V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 7.5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 20SA Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for automatic removal of nuisance water from small and medium boats. It is intended for permanent marine installation and should be selected by required flow, supply voltage, discharge-hose size and expected discharge head.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule automatic submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral timed water-sensing control\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eOptional panel switch\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for small and medium boats.\u003c\/li\u003e\n\u003cli\u003eConnect to 19 mm (3\/4 in) discharge hose.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V.\u003c\/li\u003e\n\u003cli\u003eA compatible Rule panel switch may be fitted where manual override or status control is required.\u003c\/li\u003e\n\u003cli\u003eNo separate external float switch is needed for automatic operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Does the Automatic Operation Work?\u003c\/h4\u003e\u003cp\u003eYes - integral timed water-sensing operation; no separate float switch required The published automatic check cycle is pump checks for water every 2.5 minutes. Separate float switch required: No.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 800 GPH (3,028 LPH; approx. 50 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 120 x 74 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 7.5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 615 GPH (2,328 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 425 GPH (1,608 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 1232R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while maintaining access for cleaning. Wire directly through the specified fuse and follow the manufacturer wiring diagram for any manual-override lead. Keep electrical joints above the maximum bilge-water level, minimise hose length and bends, prevent siphoning, and test automatic operation before leaving the vessel unattended.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eKeep the automatic sensor or float-switch movement clear of oil, dirt and debris.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 800 GPH (3,028 LPH; approx. 50 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eIntegral automatic water checking every 2.5 minutes\u003c\/li\u003e\n\u003cli\u003eNo separate float switch required\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eDoes this automatic pump need a float switch?\u003c\/strong\u003e\u003cbr\u003eNo. The automatic control is built into the pump.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy does the pump run briefly when the bilge appears dry?\u003c\/strong\u003e\u003cbr\u003eThe pump checks for water at 2.5-minute intervals. It stops after the short check when no water resistance is detected.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage: 12V. Also confirm the hose size, fuse rating and available installation space.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the stated flow equal the installed flow?\u003c\/strong\u003e\u003cbr\u003eThe stated capacity is an open-flow rating. Actual output falls as discharge head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e20SA\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eAutomatic submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-20SA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e800 GPH (3,028 LPH; approx. 50 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes - integral timed water-sensing operation; no separate float switch required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3.4A at 12V; 4.3A at 13.6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e7.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e615 GPH (2,328 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e425 GPH (1,608 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e120 x 74 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm (3\/4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1232R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic check cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003ePump checks for water every 2.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSeparate float switch required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"Default Title","offer_id":47309873053973,"sku":"CW-20SA","price":109.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/27dapic_3b66ad32-b1b7-4f4e-b0d1-f0855e55d341.jpg?v=1697548116"},{"product_id":"rule-lopro-automatic-12v-submersible-pump-lp900s-cw-lp900s","title":"Rule LoPro LP900S Low Profile Automatic Submersible Bilge Pump","description":"\u003cp\u003eThe Rule LP900S LoPro is a low-profile 12V bilge pump rated at 900 GPH (3,407 LPH; approx. 57 litres\/minute). It measures only 58.4 mm high and supports automatic level-sensing or 2.5-minute timed water-check operation.\u003c\/p\u003e\u003cp\u003eThe Rule LP900S is designed for shallow bilges and restricted spaces where a conventional upright pump cannot fit. Its rotating discharge body, horizontal or vertical mounting options and supplied port adapters allow the outlet to be aligned around structural members and other equipment.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule LoPro LP900S Automatic Submersible Bilge Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e LP900S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-LP900S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Low-profile automatic bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 900 GPH (3,407 LPH; approx. 57 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 7.5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule LP900S Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used to remove nuisance bilge water from boats with limited vertical clearance, including shallow bilge compartments beneath floors, engines or machinery.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule LoPro bilge pump\u003c\/li\u003e\n\u003cli\u003e19 mm, 25 mm and 28 mm straight discharge ports\u003c\/li\u003e\n\u003cli\u003e19 mm 90-degree discharge elbow\u003c\/li\u003e\n\u003cli\u003eIntegral backflow-prevention valve system\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine wiring\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and 7.5A fuse\u003c\/li\u003e\n\u003cli\u003eOptional panel switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFor 12V DC marine electrical systems.\u003c\/li\u003e\n\u003cli\u003eCompatible with 19 mm, 25 mm or 28 mm straight hose connections, plus a 19 mm 90-degree elbow supplied with the pump.\u003c\/li\u003e\n\u003cli\u003eCan be mounted horizontally or vertically.\u003c\/li\u003e\n\u003cli\u003eThe discharge body rotates to simplify hose alignment.\u003c\/li\u003e\n\u003cli\u003eNo separate float switch is required for automatic operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Does the Automatic Operation Work?\u003c\/h4\u003e\u003cp\u003eAutomatic level-sensing or 2.5-minute timed water-check operation\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 900 GPH (3,407 LPH; approx. 57 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 237.5 x 58.4 x 58.4 mm (L x W x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 7.5A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Integral check-valve arrangement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849; ISO 8846\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Horizontal or vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge body:\u003c\/strong\u003e Rotating for hose alignment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eSelect the mounting orientation that keeps the inlet at the lowest practical bilge point while allowing access for cleaning. Use the largest practical discharge route with minimal bends, provide anti-siphon protection where required, keep electrical joints above the maximum bilge-water level and fit a 7.5A fuse close to the power source. Test the complete system after installation.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eKeep the automatic sensor or float-switch movement clear of oil, dirt and debris.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e900 GPH (3,407 LPH) nominal open-flow capacity\u003c\/li\u003e\n\u003cli\u003eLow-profile 58.4 mm-high body\u003c\/li\u003e\n\u003cli\u003e12V DC, 4A current draw and 7.5A recommended fuse\u003c\/li\u003e\n\u003cli\u003eHorizontal or vertical installation\u003c\/li\u003e\n\u003cli\u003eRotating discharge body and four supplied port options\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off and backflow prevention\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE, ISO 8849 and ISO 8846 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eWhat is the difference between the LP900S and LP900D?\u003c\/strong\u003e\u003cbr\u003eThe LP900S has integral automatic sensing and timed-check modes. The LP900D is non-automatic and uses an external float switch and\/or panel switch.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich hose connection should I use?\u003c\/strong\u003e\u003cbr\u003eChoose the port that matches the discharge hose and gives the least restricted route. Straight 19 mm, 25 mm and 28 mm ports and a 19 mm elbow are supplied.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan the pump be mounted horizontally?\u003c\/strong\u003e\u003cbr\u003eYes. Both LoPro models support horizontal or vertical mounting.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the full 900 GPH reach the discharge outlet?\u003c\/strong\u003e\u003cbr\u003eThe 900 GPH figure is an open-flow rating. Installed flow reduces with head height, hose resistance, bends and voltage drop.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eLP900S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eLow-profile automatic bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-LP900S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e900 GPH (3,407 LPH; approx. 57 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e7.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eAutomatic level-sensing or 2.5-minute timed water-check operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e237.5 x 58.4 x 58.4 mm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm, 25 mm or 28 mm straight hose barb; 19 mm 90-degree elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eHorizontal or vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRotating for hose alignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eIntegral check-valve arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849; ISO 8846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic level settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eApprox. 50 mm or 32.5 mm, selected by installation orientation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eTimed-check mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eChecks for water every 2.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"Default Title","offer_id":47309880033557,"sku":"CW-LP900S","price":98.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/lp900-lopro-20900s.jpg?v=1698135303"},{"product_id":"rule-lopro-lp900d-low-profile-submersible-bilge-pump","title":"Rule LoPro LP900D Low Profile Submersible Bilge Pump","description":"\u003cp\u003eThe Rule LP900D LoPro is a low-profile 12V bilge pump rated at 900 GPH (3,407 LPH; approx. 57 litres\/minute). It measures only 58.4 mm high and supports non-automatic operation using a separate float switch and\/or panel switch.\u003c\/p\u003e\u003cp\u003eThe Rule LP900D is designed for shallow bilges and restricted spaces where a conventional upright pump cannot fit. Its rotating discharge body, horizontal or vertical mounting options and supplied port adapters allow the outlet to be aligned around structural members and other equipment.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule LoPro LP900D Submersible Bilge Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e LP900D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-LP900D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Low-profile standard bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 900 GPH (3,407 LPH; approx. 57 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 7.5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule LP900D Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used to remove nuisance bilge water from boats with limited vertical clearance, including shallow bilge compartments beneath floors, engines or machinery.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule LoPro bilge pump\u003c\/li\u003e\n\u003cli\u003e19 mm, 25 mm and 28 mm straight discharge ports\u003c\/li\u003e\n\u003cli\u003e19 mm 90-degree discharge elbow\u003c\/li\u003e\n\u003cli\u003eIntegral backflow-prevention valve system\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine wiring\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and 7.5A fuse\u003c\/li\u003e\n\u003cli\u003eFloat switch and panel switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFor 12V DC marine electrical systems.\u003c\/li\u003e\n\u003cli\u003eCompatible with 19 mm, 25 mm or 28 mm straight hose connections, plus a 19 mm 90-degree elbow supplied with the pump.\u003c\/li\u003e\n\u003cli\u003eCan be mounted horizontally or vertically.\u003c\/li\u003e\n\u003cli\u003eThe discharge body rotates to simplify hose alignment.\u003c\/li\u003e\n\u003cli\u003eA separate suitably rated float switch and\/or panel switch is required for automatic operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIs a Separate Float Switch Required?\u003c\/h4\u003e\u003cp\u003eNon-automatic operation using a separate float switch and\/or panel switch\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 900 GPH (3,407 LPH; approx. 57 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 193 x 58.4 x 58.4 mm (L x W x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 7.5A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Integral check-valve arrangement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849; ISO 8846\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Horizontal or vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge body:\u003c\/strong\u003e Rotating for hose alignment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eSelect the mounting orientation that keeps the inlet at the lowest practical bilge point while allowing access for cleaning. Use the largest practical discharge route with minimal bends, provide anti-siphon protection where required, keep electrical joints above the maximum bilge-water level and fit a 7.5A fuse close to the power source. Test the complete system after installation.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e900 GPH (3,407 LPH) nominal open-flow capacity\u003c\/li\u003e\n\u003cli\u003eLow-profile 58.4 mm-high body\u003c\/li\u003e\n\u003cli\u003e12V DC, 4A current draw and 7.5A recommended fuse\u003c\/li\u003e\n\u003cli\u003eHorizontal or vertical installation\u003c\/li\u003e\n\u003cli\u003eRotating discharge body and four supplied port options\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off and backflow prevention\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE, ISO 8849 and ISO 8846 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eWhat is the difference between the LP900S and LP900D?\u003c\/strong\u003e\u003cbr\u003eThe LP900S has integral automatic sensing and timed-check modes. The LP900D is non-automatic and uses an external float switch and\/or panel switch.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich hose connection should I use?\u003c\/strong\u003e\u003cbr\u003eChoose the port that matches the discharge hose and gives the least restricted route. Straight 19 mm, 25 mm and 28 mm ports and a 19 mm elbow are supplied.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan the pump be mounted horizontally?\u003c\/strong\u003e\u003cbr\u003eYes. Both LoPro models support horizontal or vertical mounting.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the full 900 GPH reach the discharge outlet?\u003c\/strong\u003e\u003cbr\u003eThe 900 GPH figure is an open-flow rating. Installed flow reduces with head height, hose resistance, bends and voltage drop.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eLP900D\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eLow-profile standard bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-LP900D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e900 GPH (3,407 LPH; approx. 57 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e7.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNon-automatic operation using a separate float switch and\/or panel switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e193 x 58.4 x 58.4 mm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm, 25 mm or 28 mm straight hose barb; 19 mm 90-degree elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eHorizontal or vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRotating for hose alignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eIntegral check-valve arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849; ISO 8846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSeparate switch required for automatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"Default Title","offer_id":47309880164629,"sku":"ASAP-504164","price":73.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/lp900-lopro-20900d.jpg?v=1698136676"},{"product_id":"rule-round-bilge-pump-800-gph-12-volt-cw-20da","title":"Rule 20DA 800 Series Submersible Bilge Pump - 800 GPH","description":"\u003cp\u003eThe Rule 20DA \/ 20DA-24 is a non-automatic submersible bilge pump rated at 800 GPH (3,028 LPH; approx. 50 litres\/minute). It is designed for bilge-water removal in small and medium boats, uses 19 mm (3\/4 in) discharge hose and requires a suitably rated float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003eThe Rule 20DA \/ 20DA-24 removes nuisance water from a boat bilge using a fully submersible centrifugal pump. The snap-lock strainer provides access to the impeller area for routine cleaning, while the stainless-steel shaft, blocked marine wiring, corrosion-resistant housing and built-in thermal cut-off are intended for permanent marine installation.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 20DA 800 Series Submersible Bilge Pump - 800 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 20DA \/ 20DA-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-20DA \/ CW-20DA-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Standard submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 800 GPH (3,028 LPH; approx. 50 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e No - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 3.4A at 12V; 4.3A at 13.6V \/ 1.7A at 24V; 2.0A at 27.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 7.5A \/ 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 20DA \/ 20DA-24 Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for bilge-water removal in small and medium boats. It is a standard, non-automatic pump: power must be controlled by a separate Rule float switch, compatible panel switch or another correctly rated control device.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFloat switch or control panel\u003c\/li\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for bilge-water removal in small and medium boats.\u003c\/li\u003e\n\u003cli\u003eConnect to 19 mm (3\/4 in) discharge hose and a correctly positioned above-waterline discharge outlet.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V \/ 24V.\u003c\/li\u003e\n\u003cli\u003eUse only with switching, cabling and circuit protection rated for the pump voltage and current.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIs a Separate Float Switch Required?\u003c\/h4\u003e\u003cp\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/p\u003e\u003ch4\u003eWhich Voltage Should I Choose?\u003c\/h4\u003e\u003cp\u003eChoose the version that matches the vessel electrical system: 12V DC \/ 24V DC. A pump must only be connected to its stated DC supply voltage.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 800 GPH (3,028 LPH; approx. 50 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 111 x 74 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 7.5A \/ 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 615 GPH (2,328 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 425 GPH (1,608 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 1232R\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while retaining access for strainer cleaning. Keep all electrical joints above the maximum anticipated bilge-water level, fit the manufacturer-specified fuse close to the power source, minimise hose length and bends, and route the discharge to prevent siphoning or backflow. Test both manual and automatic control after installation and during routine vessel checks.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 800 GPH (3,028 LPH; approx. 50 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eNon-automatic design for use with a separate switch\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer base and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eMarine-grade blocked wiring and stainless-steel shaft\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003cli\u003eBackflow prevention and vented impeller housing\u003c\/li\u003e\n\u003cli\u003e12V and 24V variants\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eIs this Rule bilge pump automatic?\u003c\/strong\u003e\u003cbr\u003eNo. It is a standard pump and requires a separate float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage. Do not connect a 12V \/ 24V pump to a different-voltage circuit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the pump deliver the full rated output after installation?\u003c\/strong\u003e\u003cbr\u003eNot necessarily. The published rating is an open-flow figure; actual delivery falls as vertical head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this pump replace routine bilge inspection?\u003c\/strong\u003e\u003cbr\u003eNo. A bilge pump is one part of a vessel water-management system. Inspect the bilge, hoses, wiring, discharge outlet and switch regularly.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e20DA\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e20DA-24\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-20DA\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-20DA-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e800 GPH (3,028 LPH; approx. 50 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e800 GPH (3,028 LPH; approx. 50 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3.4A at 12V; 4.3A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1.7A at 24V; 2.0A at 27.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e7.5A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e615 GPH (2,328 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e615 GPH (2,328 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e425 GPH (1,608 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e425 GPH (1,608 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e111 x 74 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e111 x 74 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm (3\/4 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm (3\/4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1232R\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1232R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"12v","offer_id":54838012248441,"sku":"ASAP-JAB-20DA","price":60.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54838012281209,"sku":"ASAP-JAB-20DA-24","price":67.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/20da.jpg?v=1698136548"},{"product_id":"rule-10-12-2000-series-submersible-bilge-pump-2000-gph","title":"Rule 10 \/ 12 2000 Series Submersible Bilge Pump - 2000 GPH","description":"\u003cp\u003eThe Rule 10 \/ 12 is a non-automatic submersible bilge pump rated at 2,000 GPH (7,571 LPH; approx. 126 litres\/minute). It is designed for medium-to-high-capacity bilge drainage on yachts and motor cruisers, uses 29 mm (1-1\/8 in) discharge hose and requires a suitably rated float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003eThe Rule 10 \/ 12 removes nuisance water from a boat bilge using a fully submersible centrifugal pump. The snap-lock strainer provides access to the impeller area for routine cleaning, while the stainless-steel shaft, blocked marine wiring, corrosion-resistant housing and built-in thermal cut-off are intended for permanent marine installation.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 10 \/ 12 2000 Series Submersible Bilge Pump - 2000 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 10 \/ 12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-10 \/ CW-12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Standard submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 2,000 GPH (7,571 LPH; approx. 126 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e No - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 29 mm (1-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 7.3A at 12V; 8.6A at 13.6V \/ 4.0A at 24V; 6.0A at 27.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 15A \/ 7.5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 10 \/ 12 Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for medium-to-high-capacity bilge drainage on yachts and motor cruisers. It is a standard, non-automatic pump: power must be controlled by a separate Rule float switch, compatible panel switch or another correctly rated control device.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFloat switch or control panel\u003c\/li\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for medium-to-high-capacity bilge drainage on yachts and motor cruisers.\u003c\/li\u003e\n\u003cli\u003eConnect to 29 mm (1-1\/8 in) discharge hose and a correctly positioned above-waterline discharge outlet.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V \/ 24V.\u003c\/li\u003e\n\u003cli\u003eUse only with switching, cabling and circuit protection rated for the pump voltage and current.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIs a Separate Float Switch Required?\u003c\/h4\u003e\u003cp\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/p\u003e\u003ch4\u003eWhich Voltage Should I Choose?\u003c\/h4\u003e\u003cp\u003eChoose the version that matches the vessel electrical system: 12V DC \/ 24V DC. A pump must only be connected to its stated DC supply voltage.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 2,000 GPH (7,571 LPH; approx. 126 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 29 mm (1-1\/8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 152 x 108 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 15A \/ 7.5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 1,620 GPH (6,132 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 1,300 GPH (4,921 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 278\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e No integral non-return valve stated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while retaining access for strainer cleaning. Keep all electrical joints above the maximum anticipated bilge-water level, fit the manufacturer-specified fuse close to the power source, minimise hose length and bends, and route the discharge to prevent siphoning or backflow. Test both manual and automatic control after installation and during routine vessel checks.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 2,000 GPH (7,571 LPH; approx. 126 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eNon-automatic design for use with a separate switch\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer base and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eMarine-grade blocked wiring and stainless-steel shaft\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003cli\u003e12V model 10 and 24V model 12 options\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eIs this Rule bilge pump automatic?\u003c\/strong\u003e\u003cbr\u003eNo. It is a standard pump and requires a separate float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage. Do not connect a 12V \/ 24V pump to a different-voltage circuit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the pump deliver the full rated output after installation?\u003c\/strong\u003e\u003cbr\u003eNot necessarily. The published rating is an open-flow figure; actual delivery falls as vertical head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this pump replace routine bilge inspection?\u003c\/strong\u003e\u003cbr\u003eNo. A bilge pump is one part of a vessel water-management system. Inspect the bilge, hoses, wiring, discharge outlet and switch regularly.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e10\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e12\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-10\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,000 GPH (7,571 LPH; approx. 126 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,000 GPH (7,571 LPH; approx. 126 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e7.3A at 12V; 8.6A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4.0A at 24V; 6.0A at 27.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e7.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,620 GPH (6,132 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,620 GPH (6,132 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,300 GPH (4,921 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1,300 GPH (4,921 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e152 x 108 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e152 x 108 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e29 mm (1-1\/8 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e29 mm (1-1\/8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e278\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo integral non-return valve stated\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo integral non-return valve stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"12v","offer_id":54838028403065,"sku":"ASAP-504112","price":260.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54838028435833,"sku":"ASAP-504114","price":260.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/888e8c3.png?v=1696422747"},{"product_id":"rule-56d-4000-series-submersible-bilge-pump-4000-gph","title":"Rule 56D 4000 Series Submersible Bilge Pump - 4000 GPH","description":"\u003cp\u003eThe Rule 56D \/ 56D-24 is a non-automatic submersible bilge pump rated at 4,000 GPH (15,140 LPH; approx. 252 litres\/minute). It is designed for high-capacity bilge drainage on larger yachts, motor cruisers and workboats, uses 51 mm (2 in) discharge hose and requires a suitably rated float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003eThe Rule 56D \/ 56D-24 removes nuisance water from a boat bilge using a fully submersible centrifugal pump. The snap-lock strainer provides access to the impeller area for routine cleaning, while the stainless-steel shaft, blocked marine wiring, corrosion-resistant housing and built-in thermal cut-off are intended for permanent marine installation.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 56D 4000 Series Submersible Bilge Pump - 4000 GPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 56D \/ 56D-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-56D \/ CW-56D-24\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Standard submersible bilge pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 4,000 GPH (15,140 LPH; approx. 252 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic operation:\u003c\/strong\u003e No - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 51 mm (2 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 10.2A at 12V; 12.1A at 13.6V \/ 6.9A at 24V; 10.0A at 27.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse:\u003c\/strong\u003e 25A \/ 15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 56D \/ 56D-24 Bilge Pump Used For?\u003c\/h4\u003e\u003cp\u003eThis pump is used for high-capacity bilge drainage on larger yachts, motor cruisers and workboats. It is a standard, non-automatic pump: power must be controlled by a separate Rule float switch, compatible panel switch or another correctly rated control device.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eIntegral or snap-lock strainer base\u003c\/li\u003e\n\u003cli\u003eFactory-fitted marine-grade electrical leads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFloat switch or control panel\u003c\/li\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003eCable extensions, waterproof connectors and circuit-protection fuse\u003c\/li\u003e\n\u003cli\u003eInstallation hardware not supplied with the packaged pump\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Pump Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSuitable for high-capacity bilge drainage on larger yachts, motor cruisers and workboats.\u003c\/li\u003e\n\u003cli\u003eConnect to 51 mm (2 in) discharge hose and a correctly positioned above-waterline discharge outlet.\u003c\/li\u003e\n\u003cli\u003eChoose the variant that matches the vessel electrical system: 12V \/ 24V.\u003c\/li\u003e\n\u003cli\u003eUse only with switching, cabling and circuit protection rated for the pump voltage and current.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eIs a Separate Float Switch Required?\u003c\/h4\u003e\u003cp\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/p\u003e\u003ch4\u003eWhich Voltage Should I Choose?\u003c\/h4\u003e\u003cp\u003eChoose the version that matches the vessel electrical system: 12V DC \/ 24V DC. A pump must only be connected to its stated DC supply voltage.\u003c\/p\u003e\u003ch4\u003eHow Do I Select the Correct Pump?\u003c\/h4\u003e\u003cp\u003eConfirm the complete installation rather than selecting by nominal GPH rating alone:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12V DC \/ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 4,000 GPH (15,140 LPH; approx. 252 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 51 mm (2 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled space:\u003c\/strong\u003e 197 x 121 mm (H x W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit protection:\u003c\/strong\u003e 25A \/ 15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 1 m head:\u003c\/strong\u003e 3,527 GPH (13,351 LPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow at 2 m head:\u003c\/strong\u003e 2,952 GPH (11,174 LPH)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDoes the Published Flow Equal the Installed Flow?\u003c\/h4\u003e\u003cp\u003eNo. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.\u003c\/p\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement strainer part number:\u003c\/strong\u003e 279\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e No integral non-return valve stated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge while retaining access for strainer cleaning. Keep all electrical joints above the maximum anticipated bilge-water level, fit the manufacturer-specified fuse close to the power source, minimise hose length and bends, and route the discharge to prevent siphoning or backflow. Test both manual and automatic control after installation and during routine vessel checks.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eNominal open-flow capacity: 4,000 GPH (15,140 LPH; approx. 252 litres\/minute)\u003c\/li\u003e\n\u003cli\u003eNon-automatic design for use with a separate switch\u003c\/li\u003e\n\u003cli\u003eEasy-clean strainer base and accessible impeller cavity\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003eMarine-grade blocked wiring and stainless-steel shaft\u003c\/li\u003e\n\u003cli\u003eIgnition protected; CE and ISO 8849 compliant\u003c\/li\u003e\n\u003cli\u003eHigh-capacity 51 mm discharge connection\u003c\/li\u003e\n\u003cli\u003e12V and 24V variants\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eIs this Rule bilge pump automatic?\u003c\/strong\u003e\u003cbr\u003eNo. It is a standard pump and requires a separate float switch and\/or panel switch for automatic operation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I choose between the available variants?\u003c\/strong\u003e\u003cbr\u003eSelect the model that matches the vessel supply voltage. Do not connect a 12V \/ 24V pump to a different-voltage circuit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the pump deliver the full rated output after installation?\u003c\/strong\u003e\u003cbr\u003eNot necessarily. The published rating is an open-flow figure; actual delivery falls as vertical head, hose length, bends, restrictions and voltage drop increase.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this pump replace routine bilge inspection?\u003c\/strong\u003e\u003cbr\u003eNo. A bilge pump is one part of a vessel water-management system. Inspect the bilge, hoses, wiring, discharge outlet and switch regularly.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e56D\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e56D-24\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-56D\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCW-56D-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4,000 GPH (15,140 LPH; approx. 252 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4,000 GPH (15,140 LPH; approx. 252 litres\/minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e10.2A at 12V; 12.1A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e6.9A at 24V; 10.0A at 27.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e25A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3,527 GPH (13,351 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e3,527 GPH (13,351 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,952 GPH (11,174 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2,952 GPH (11,174 LPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e197 x 121 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e197 x 121 mm (H x W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e51 mm (2 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e51 mm (2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e279\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e279\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo integral non-return valve stated\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo integral non-return valve stated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"12v","offer_id":54837974106489,"sku":"ASAP-504132","price":241.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54837974139257,"sku":"ASAP-504134","price":272.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/56d24_4a2bfd0d-a627-4888-bc28-d0aa66cf2ac9.jpg?v=1698134971"},{"product_id":"seaflo-bilge-pump-automatic-13b-1100gph","title":"SEAFLO Bilge Pump 1100GPH Automatic Auto 13B Series - 12v","description":"\u003cp\u003eThe compact Seaflo 13B series bilge pump uses an inbuilt electronic sensor to regulate it's operation eliminating the need for a separate float switch.\u003c\/p\u003e\n\u003cp\u003eThe pumps impeller is set to turn for half a second every 2.5 minutes, if it senses any resistance it will continue pumping until all the water is removed but is also equipped with a back-up feature that prevents it running continuously if the sensor is fouled by loose debris. Back flow is prevented by an internal check flow valve. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectronic timer sensing automatic bilge pump\u003c\/li\u003e\n\u003cli\u003eRemovable strainer\/impeller area\u003c\/li\u003e\n\u003cli\u003eEasy maintenance\u003c\/li\u003e\n\u003cli\u003eRobust, long life engine\u003c\/li\u003e\n\u003cli\u003eFully submersible with unique moisture-proof seal\u003c\/li\u003e\n\u003cli\u003eIgnition protected and fireproof\u003c\/li\u003e\n\u003cli\u003eAnti-airlock protection\u003c\/li\u003e\n\u003cli\u003eEnclosed marine grade silcone, tin plated wiring\u003c\/li\u003e\n\u003cli\u003eCheck valve prevents any water back flow\u003c\/li\u003e\n\u003cli\u003eBack up feature prevents continuous running if fouled by debris\u003c\/li\u003e\n\u003cli\u003eVolts:12v\u003c\/li\u003e\n\u003cli\u003eCurrent: 4.0A\u003c\/li\u003e\n\u003cli\u003eHead: 4m \/ 13'\u003c\/li\u003e\n\u003cli\u003eOutlet: 25mm \/ 1\"\u003c\/li\u003e\n\u003cli\u003eWire 18 AWG x 1m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003ca href=\"\/image\/product\/seaflo\/SFBP1(2)-G(600_4700)-13A(B-C-D-E)%20%20%2013%20Series%20bilge%20pump.pdf\" title=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/files\/SFBP1_2_-G_600_4700_-13A_B-C-D-E_13_Series_bilge_pump.pdf?v=1695808057\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"color: #e74c3c;\"\u003eInstructions - Click Here\u003c\/span\u003e\u003c\/a\u003e\u003c\/h2\u003e","brand":"SEAFLO","offers":[{"title":"Default Title","offer_id":47309920272661,"sku":"BR-BP1G110013B","price":82.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/SFBP1_2_-G600_800-1100_-13B_2.jpg?v=1698135180"},{"product_id":"clone-of-seaflo-bilge-pump-1100gph-automatic-auto-13b-series-12v","title":"SEAFLO Bilge Pump 1100GPH Non-Automatic Manual 13A Series - 12v","description":"\u003cp\u003eFully moisture-proof and fully submersible, the 13A Series, non-automatic submersible bilge pumps are operated via a float switch or panel switch. The quietly running pumps feature a snap-off strainer base for easy maintenance, ignition and anti-airlock protection, and an integral valve to check and prevent any back flow of water. A quick-connect joint, with a split lock nut design, allows the pump to be replaced in seconds without the need to dismantle the water pipe. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNon Auto - for use with panel switch or float switch (available separately)\u003c\/li\u003e\n\u003cli\u003eQuiet running\u003c\/li\u003e\n\u003cli\u003eQuick-connect joint for easy installation and maintenance\u003c\/li\u003e\n\u003cli\u003eIgnition protection\u003c\/li\u003e\n\u003cli\u003eAnti-airlock protection\u003c\/li\u003e\n\u003cli\u003eMoisture tight sealing\u003c\/li\u003e\n\u003cli\u003eMarine grade silicon blocked and tin coated wire\u003c\/li\u003e\n\u003cli\u003eStainless steel motor shaft\u003c\/li\u003e\n\u003cli\u003eSnap lock strainer base\u003c\/li\u003e\n\u003cli\u003eStrainer base will fit industry standard\u003c\/li\u003e\n\u003cli\u003eCE, RoHS, ISO8846 and ISO8849 standards\u003c\/li\u003e\n\u003cli\u003eFlow rate: 800gph\/3028lph\u003c\/li\u003e\n\u003cli\u003eVoltage: 12V\u003c\/li\u003e\n\u003cli\u003eCurrent: 3.5A\u003c\/li\u003e\n\u003cli\u003eHead: 3m \/ 10ft\u003c\/li\u003e\n\u003cli\u003eOutlet: 29mm \/ 1 1\/8\" and 29mm \/ 1 1\/8\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/files\/SFBP1_2_-G_600_4700_-13A_B-C-D-E_13_Series_bilge_pump.pdf?v=1695808057\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"color: #e74c3c;\"\u003eInstructions - Click Here\u003c\/span\u003e\u003c\/a\u003e\u003c\/h1\u003e\n\u003ch2 style=\"text-align: center;\"\u003e \u003c\/h2\u003e","brand":"SEAFLO","offers":[{"title":"Default Title","offer_id":47309921779989,"sku":"BR-BP1G110013A","price":34.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/SFBP1_2_-G600_800-1100_-13B_2_4a1bd5aa-7468-4671-bf46-b6c0351050d6.jpg?v=1698136674"},{"product_id":"seaflo-bilge-pump-manual-13a-1500gph","title":"SEAFLO Bilge Pump 1500GPH Non-Automatic Manual 13A Series - 12v","description":"\u003cp\u003eThe compact Seaflo 13B series bilge pump uses an inbuilt electronic sensor to regulate it's operation eliminating the need for a separate float switch. The pumps impeller is set to turn for half a second every 2.5 minutes, if it senses any resistance it will continue pumping until all the water is removed but is also equipped a back-up feature that prevents it running continuously if the sensor is fouled by loose debris. Back flow is prevented by an internal check flow valve. The robust pump is entirely submersible, uniquely sealed with ignition protect and is quiet in operation. A snap-off strainer and easily removable impeller make maintenance easy. The pack contains a removable threaded straight body outlet.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectronic timer sensing automatic bilge pump\u003c\/li\u003e\n\u003cli\u003eRemovable strainer\/impeller area\u003c\/li\u003e\n\u003cli\u003eEasy maintenance\u003c\/li\u003e\n\u003cli\u003eRobust, long life engine\u003c\/li\u003e\n\u003cli\u003eFully submersible with unique moisture-proof seal\u003c\/li\u003e\n\u003cli\u003eIgnition protected and fireproof\u003c\/li\u003e\n\u003cli\u003eAnti-airlock protection\u003c\/li\u003e\n\u003cli\u003eEnclosed marine grade silcone, tin plated wiring\u003c\/li\u003e\n\u003cli\u003eCheck valve prevents any water back flow\u003c\/li\u003e\n\u003cli\u003eBack up feature prevents continuous running if fouled by debris\u003c\/li\u003e\n\u003cli\u003eVolts:12v\u003c\/li\u003e\n\u003cli\u003eCurrent: 4.5A\u003c\/li\u003e\n\u003cli\u003eHead: 5m \/ 16'\u003c\/li\u003e\n\u003cli\u003eOutlet: 29mm \/ 1 1\/8\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/files\/SFBP1_2_-G_600_4700_-13A_B-C-D-E_13_Series_bilge_pump.pdf?v=1695808057\"\u003e\u003cspan style=\"color: #e74c3c;\"\u003eInstructions - Click Here\u003c\/span\u003e\u003c\/a\u003e\u003c\/h2\u003e","brand":"SEAFLO","offers":[{"title":"Default Title","offer_id":47309921911061,"sku":"BR-BP1G150013A","price":67.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/SFBP1_2_-G1500_2000_-13A_2.jpg?v=1696422983"},{"product_id":"seaflo-bilge-pump-manual-01-350gph","title":"SEAFLO Bilge Pump 350GPH Non-Automatic Manual 01 Series - 12v","description":"\u003cp\u003eFully moisture-proof and fully submersible, the 01 Series, non-automatic submersible bilge pumps are operated via a float switch or panel switch. The pump features a snap off strainer base for easy maintenance, ignition and anti-airlock protection and is quiet in operation. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMoisture tight sealing \u003c\/li\u003e\n\u003cli\u003eAnti-airlock protection\u003c\/li\u003e\n\u003cli\u003eMarine grade blocked wire\u003c\/li\u003e\n\u003cli\u003eStainless steel shaft\u003c\/li\u003e\n\u003cli\u003eStrainer base will fit industry standard\u003c\/li\u003e\n\u003cli\u003eRun dry capable, with normal workloads\u003c\/li\u003e\n\u003cli\u003eVoltage: 12V\u003c\/li\u003e\n\u003cli\u003eCurrent: 1.0A\u003c\/li\u003e\n\u003cli\u003eHead: 3m\/19'\u003c\/li\u003e\n\u003cli\u003eOutlet: 19mm \/ 3\/4\"\u003c\/li\u003e\n\u003cli\u003eWire: 18 AWG x 1m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/files\/BP1G50001.pdf?v=1695808095\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"color: #e74c3c;\"\u003eInstructions - Click Here\u003c\/span\u003e\u003c\/a\u003e\u003c\/h2\u003e","brand":"SEAFLO","offers":[{"title":"Default Title","offer_id":47309922140437,"sku":"BR-BP1G35001","price":15.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/SFBP1-G350-01_1.jpg?v=1696422986"},{"product_id":"seaflo-bilge-pump-automatic-13b-600gph","title":"SEAFLO Bilge Pump 600GPH Automatic Auto 13B Series - 12v","description":"\u003cp\u003eThe compact Seaflo 13B series bilge pump uses an inbuilt electronic sensor to regulate it's operation eliminating the need for a separate float switch.\u003c\/p\u003e\n\u003cp\u003eThe pumps impeller is set to turn for half a second every 2.5 minutes, if it senses any resistance it will continue pumping until all the water is removed but is also equipped with a back-up feature that prevents it running continuously if the sensor is fouled by loose debris. Back flow is prevented by an internal check flow valve. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectronic timer sensing automatic bilge pump\u003c\/li\u003e\n\u003cli\u003eRemovable strainer\/impeller area\u003c\/li\u003e\n\u003cli\u003eEasy maintenance\u003c\/li\u003e\n\u003cli\u003eRobust, long life engine\u003c\/li\u003e\n\u003cli\u003eFully submersible with unique moisture-proof seal\u003c\/li\u003e\n\u003cli\u003eIgnition protected and fireproof\u003c\/li\u003e\n\u003cli\u003eAnti-airlock protection\u003c\/li\u003e\n\u003cli\u003eEnclosed marine grade silcone, tin plated wiring\u003c\/li\u003e\n\u003cli\u003eCheck valve prevents any water back flow\u003c\/li\u003e\n\u003cli\u003eBack up feature prevents continuous running if fouled by debris\u003c\/li\u003e\n\u003cli\u003eVolts:12v\u003c\/li\u003e\n\u003cli\u003eCurrent: 2.5A\u003c\/li\u003e\n\u003cli\u003eHead: 2.5m \/ 7.5'\u003c\/li\u003e\n\u003cli\u003eOutlet: 19mm \/ 3\/4\" and 29mm \/ 1 1\/8\"\u003c\/li\u003e\n\u003cli\u003eWire 18 AWG x 1m\u003c\/li\u003e\n\u003cli\u003eWeight: 0.4g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/files\/SFBP1_2_-G_600_4700_-13A_B-C-D-E_13_Series_bilge_pump.pdf?v=1695808057\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"color: #e74c3c;\"\u003eInstructions - Click Here\u003c\/span\u003e\u003c\/a\u003e\u003c\/h2\u003e","brand":"SEAFLO","offers":[{"title":"Default Title","offer_id":47309923320085,"sku":"BR-BP1G60013B","price":53.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/SFBP1_2_-G600_800-1100_-13B_1.jpg?v=1699351835"},{"product_id":"seaflo-bilge-pump-automatic-13b-800gph","title":"SEAFLO Bilge Pump 800GPH Automatic Auto 13B Series - 12v","description":"\u003cp\u003eThe compact Seaflo 13B series bilge pump uses an inbuilt electronic sensor to regulate it's operation eliminating the need for a separate float switch.\u003c\/p\u003e\n\u003cp\u003eThe pumps impeller is set to turn for half a second every 2.5 minutes, if it senses any resistance it will continue pumping until all the water is removed but is also equipped with a back-up feature that prevents it running continuously if the sensor is fouled by loose debris. Back flow is prevented by an internal check flow valve. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectronic timer sensing automatic bilge pump\u003c\/li\u003e\n\u003cli\u003eRemovable strainer\/impeller area\u003c\/li\u003e\n\u003cli\u003eEasy maintenance\u003c\/li\u003e\n\u003cli\u003eRobust, long life engine\u003c\/li\u003e\n\u003cli\u003eFully submersible with unique moisture-proof seal\u003c\/li\u003e\n\u003cli\u003eIgnition protected and fireproof\u003c\/li\u003e\n\u003cli\u003eAnti-airlock protection\u003c\/li\u003e\n\u003cli\u003eEnclosed marine grade silcone, tin plated wiring\u003c\/li\u003e\n\u003cli\u003eCheck valve prevents any water back flow\u003c\/li\u003e\n\u003cli\u003eBack up feature prevents continuous running if fouled by debris\u003c\/li\u003e\n\u003cli\u003eVolts:12v\u003c\/li\u003e\n\u003cli\u003eCurrent: 2.5A\u003c\/li\u003e\n\u003cli\u003eHead: 3m \/ 10'\u003c\/li\u003e\n\u003cli\u003eOutlet: 19mm \/ 3\/4\" and 29mm \/ 1 1\/8\"\u003c\/li\u003e\n\u003cli\u003eWire 18 AWG x 1m\u003c\/li\u003e\n\u003cli\u003eWeight: 0.4g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/files\/SFBP1_2_-G_600_4700_-13A_B-C-D-E_13_Series_bilge_pump.pdf?v=1695808057\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"color: #e74c3c;\"\u003eInstructions - Click Here\u003c\/span\u003e\u003c\/a\u003e\u003c\/h2\u003e","brand":"SEAFLO","offers":[{"title":"Default Title","offer_id":47309923746069,"sku":"BR-BP1G80013B","price":69.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/SFBP1_2_-G600_800-1100_-13B_1_de90bf67-af2b-4cd4-95c1-823fd8c32ac7.jpg?v=1699351895"},{"product_id":"seaflo-bilge-pump-low-profile-automatic-14b","title":"SEAFLO Low Profile Bilge Pump 800GPH Automatic Auto Timer Sensing 14b Series - 12v","description":"\u003cp\u003eThe Seaflo Series 14B low profile automatic bilge pumps operate via timer sensing eliminating the need for a separate float switch. The pump is timed to run every 2.5 minutes for 0.5 seconds. If resistance is felt by the presence of water, the pump will continue to run until the water is drained. This begins when the water level reaches 4.5cm.\u003c\/p\u003e\n\u003cp\u003eWith a long and narrow design the low profile Seaflo pumps are ideal for fitting into tight, awkward space whilst the outlet and pump body will rotate a full 360 degrees to facilitate installation. These versatile pumps can also be mounted vertically, horizontally or diagonally. The fully sealed, highly efficient and long-life motor uses minimum power and runs quietly. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTimer sensing automatic bilge pump\u003c\/li\u003e\n\u003cli\u003eVertical, horizontal or diagonal mount\u003c\/li\u003e\n\u003cli\u003eSealed motor\u003c\/li\u003e\n\u003cli\u003eUnique moisture-tight seal\u003c\/li\u003e\n\u003cli\u003eFive blade high flow impellor\u003c\/li\u003e\n\u003cli\u003eNon-return valve prevents backflow\u003c\/li\u003e\n\u003cli\u003eMarine grade wiring\u003c\/li\u003e\n\u003cli\u003eISO 8846, ISO8849, CE, RoHS standards\u003c\/li\u003e\n\u003cli\u003eFlow rate: 800 GPH \/ 3028 litres per minute\u003c\/li\u003e\n\u003cli\u003eVoltage: 12V\u003c\/li\u003e\n\u003cli\u003eCurrent: 3.2A\u003c\/li\u003e\n\u003cli\u003eHead: 3.2m \/ 10.5ft\u003c\/li\u003e\n\u003cli\u003eOutlet: Automatic Timer Sensor\u003c\/li\u003e\n\u003cli\u003eWire: 19mm \/ 3\/3\", 25mm \/ 1 \" and 29mm \/ 1 1\/8\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/files\/BP1G80014B.pdf?v=1695808142\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"color: #e74c3c;\"\u003eInstructions - Click Here\u003c\/span\u003e\u003c\/a\u003e\u003c\/h2\u003e","brand":"SEAFLO","offers":[{"title":"Default Title","offer_id":47309926564117,"sku":"BR-BP1G80014B","price":48.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/14B_2.jpg?v=1696423030"},{"product_id":"https-www-marinescene-co-uk-en-product-seaflo-bilge-pump-low-profile-manual-14c","title":"SEAFLO Low Profile Bilge Pump 800GPH Non Automatic Manual Timer Sensing 14C Series - 12v","description":"\u003cp\u003eWith a long and narrow design the low profile Seaflo 14C Non Automatic pumps are ideal for fitting into tight, awkward space whilst the outlet and pump body will rotate a full 360 degrees to facilitate installation. These versatile pumps can also be mounted vertically, horizontally or diagonally.. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow profile strainer for virtually dry bilge\u003c\/li\u003e\n\u003cli\u003eVertical, horizontal or diagonal mount\u003c\/li\u003e\n\u003cli\u003eFully Sealed\u003c\/li\u003e\n\u003cli\u003eUnique moisture-tight seal\u003c\/li\u003e\n\u003cli\u003eFive blade high flow impellor\u003c\/li\u003e\n\u003cli\u003eNon-return valve prevents backflow\u003c\/li\u003e\n\u003cli\u003eMarine grade wiring\u003c\/li\u003e\n\u003cli\u003eISO 8846, ISO8849, CE, RoHS standards\u003c\/li\u003e\n\u003cli\u003eFlow rate: 800 GPH \/ 3028 litres per minute\u003c\/li\u003e\n\u003cli\u003eVoltage: 12V\u003c\/li\u003e\n\u003cli\u003eCurrent: 3.2A\u003c\/li\u003e\n\u003cli\u003eHead: 3.2m \/ 10.5ft\u003c\/li\u003e\n\u003cli\u003eOutlet: \u003cspan data-mce-fragment=\"1\"\u003e19mm \/ 3\/3\", 25mm \/ 1 \" and 29mm \/ 1 1\/8\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/files\/BP1G80014B.pdf?v=1695808142\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"color: #e74c3c;\"\u003eInstructions - Click Here\u003c\/span\u003e\u003c\/a\u003e\u003c\/h2\u003e","brand":"SEAFLO","offers":[{"title":"Default Title","offer_id":47309928988949,"sku":"BR-BP1G80014C","price":26.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/14B_2_59fdb827-007f-4587-ade8-fa9dd7eb89c9.jpg?v=1696423033"},{"product_id":"seaflo-bilge-diaphragm-pump-manual","title":"SEAFLO Manual Diaphragm Bilge Pump 720GPH","description":"\u003cp\u003eA manual compact hand bilge pump made from non corrosive materials.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eBarbed inlet and outlet nozzles accommodate 32mm hoses.\u003c\/li\u003e\n\t\u003cli\u003eSurface or thru-deck mount, with a fixed handle.\u003c\/li\u003e\n\t\u003cli\u003eUp to 10 litres of water per 30 strokes in one minute.\u003c\/li\u003e\n\t\u003cli\u003eCompact bilge pump 180mm x 125mm x 75mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SEAFLO","offers":[{"title":"Default Title","offer_id":47309929218325,"sku":"BR-DHPG72001","price":25.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/2080495_l.jpg?v=1696423035"},{"product_id":"unimer-marine-drainman-extension-hose","title":"Unimer Marine Drainman Bilge Pump Extension Hose","description":"\u003cp\u003e\u003cstrong\u003eHose Length\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e3m\u003c\/p\u003e\n\n\u003cp\u003eAlt Ref: TMS-810751D\u003c\/p\u003e","brand":"Unimer Marine","offers":[{"title":"Default Title","offer_id":47319175790869,"sku":"MZ-40716","price":12.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/3529_drainman-5-result.jpg?v=1696515374"},{"product_id":"unimer-marine-drainman-bilge-pump","title":"Unimer Marine Drainman Wave Activated Bilge Pump","description":"\u003cp\u003eThe Drainman bilge pump is powered by the tugs created on the mooring line from wind, surf and waves. All natural, with no electricity that can fail.\u003c\/p\u003e\n\u003cp\u003eDrainman has been on the market for a few years with great success. Now, we introduce the second generation, featuring a new design and upgraded materials for increased durability. The new neoprene cover protects the pump from sunlight and wear and tear.\u003c\/p\u003e\n\u003cp\u003eDrainman is handy to carry, easy to install and lock into place. It can be fitted to mooring lines fore, aft or on the side of your boat. You can even place it in between your boat and dinghy.\u003c\/p\u003e\n\u003cp\u003eDrainman is made with tough materials, and can withstand forces up to 15,000 Newton. The pump works around the clock and can pump up to 2,500 litres of water every twenty-four hours. Drainman is self-priming and has a suction height of up to 2.5 metres, and a suction length of up to 8 metres.\u003c\/p\u003e\n\u003cp\u003eWater is pumped out through the hose placed in the lowest point of the boat. A small weight can be attached to, or simply placed upon, the eye-bolt at the intake to make sure the hose is positioned right. A sieve on the eye-bolt keeps dirt out of the hose, and is easy to clean. The hose is 3 metres long but can be extended to 6 metres, by using the Drainman extension hose, sold separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHose Length\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3m\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/files\/3607_drainman-install-guide.pdf?v=1695811559\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eInstall Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlt Ref: TMS-810750D\u003c\/strong\u003e\u003c\/p\u003e","brand":"Unimer Marine","offers":[{"title":"Default Title","offer_id":47319175987477,"sku":"MZ-40715","price":65.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/3526_drainman-4-result.jpg?v=1696515377"},{"product_id":"whale-as0356-compac-50-deck-plate-service-kit","title":"Whale AS0356 Compac 50 Deck Plate Service Kit","description":"\u003cdiv style=\"-webkit-text-stroke-width: 0px; text-align: start; text-indent: 0px;\"\u003e\u003cspan style=\"color: #000000;\"\u003eProvides a neat cover with aesthetic designs over manual bilge pumps. Manufactured from UV Stabilised plastic and will not fade or discolour over time. Snap-shut lid remains closed when pump is not in use. \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"-webkit-text-stroke-width: 0px; text-align: start; text-indent: 0px;\"\u003e \u003c\/div\u003e\n\u003cp\u003eThis kit contains:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1x  Gaiter\u003c\/li\u003e\n\u003cli\u003e1x Deckplate\u003c\/li\u003e\n\u003cli\u003e1x Cover for decollate\u003c\/li\u003e\n\u003cli\u003e4x Screws (M6  x  30)\u003c\/li\u003e\n\u003cli\u003e4x Nut inserts (M6)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.whalepumps.com\/marine\/siteFiles\/resources\/docs\/product-accessories-spares\/MBP_Compac50.pdf\"\u003eMore Information\u003c\/a\u003e\u003c\/p\u003e","brand":"Whale","offers":[{"title":"Default Title","offer_id":47319255154965,"sku":"MA-AS0356","price":37.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/AS0356.png?v=1696516093"},{"product_id":"whale-bilge-ic-si8284-si8484-strainer-and-gulper-ic-pump-kit","title":"Whale SI8284 \/ SI8484 Bilge IC Strainer And Gulper IC Pump Kit","description":"\u003cp\u003eWhale Bilge IC Retail Kit 12V DC Pump. Remote mounted bilge IC kit with automatic intelligent control built in. \u003c\/p\u003e\n\u003cp\u003eIncludes Gulper IC and Strainer IC with 4m (12ft) of cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to install secure fit\u003c\/li\u003e\n\u003cli\u003eNon-choke valves - no filter to block\/clean\u003c\/li\u003e\n\u003cli\u003eSelf primes and runs dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt the heart of every Whale IC product lies innovative electronic control circuitry. This enables IC sensor accessories to communicate directly with IC pumps to control their performance.\u003c\/p\u003e\n\u003cp\u003eSave time and money by reducing four separate components to one pre-wired system. Remote mounting automatic Gulper IC receives signals from Strainer IC and switches on and off automatically.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePre-wired and assembled - just connect power\u003c\/li\u003e\n\u003cli\u003eRemote mounted pump for easy inspection- high, dry and protected\u003c\/li\u003e\n\u003cli\u003eSoft start - protects the pump for long life\u003c\/li\u003e\n\u003cli\u003eSmall footprint strainer fits into very confined bilge spaces\u003c\/li\u003e\n\u003cli\u003eLow current controlled switching - no switch failure from high currents\u003c\/li\u003e\n\u003cli\u003eOn\/off delay - prevents cycling\u003c\/li\u003e\n\u003cli\u003eEnvironmentally friendly - no mercury\u003c\/li\u003e\n\u003cli\u003eTime delay to allow for optimum drainage\u003c\/li\u003e\n\u003cli\u003eOverride wire included to allow for manual activation\u003c\/li\u003e\n\u003cli\u003eNon-choke valves – no filter to block\/clean\u003c\/li\u003e\n\u003cli\u003eLong life - pump self primes and runs dry without damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cstrong\u003eThese items are usually made to order - delivery is normally up to 4 weeks.\u003c\/strong\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=WEghbGj_GBc\u0026amp;feature=youtu.be\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e","brand":"Whale","offers":[{"title":"12v","offer_id":55303360086393,"sku":"MA-SI8284","price":280.95,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":55303368671609,"sku":"MA-S18484","price":286.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/bilge-ic-large.jpg?v=1700571520"},{"product_id":"whale-titan-bilge-water-pump-standard-bp4402-ma-bp4402","title":"Whale BP4402 Gusher Titan Manual Bilge \u0026 Waste Water Transfer Pump","description":"\u003cp\u003eWhale BP4402 Gusher Titan Manual Bilge \u0026amp; Waste Water Transfer Pump.                Ref:  MA-BP4402  \u003c\/p\u003e\n\n\u003cul\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWhale manual diaphragm pump - standard.  Pumps up to 105 litres per minute. \u003c\/p\u003e\n\n\u003cp class=\"introduction\"\u003eGusher Titan is Whale’s tough lightweight proven pump. A design that has been tried tested and trusted by sailors for decades.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eWhale's high performance lightweight model.\u003c\/li\u003e\n\t\u003cli\u003eHigh flow rate: 105 ltrs (28 US gals) per minute\u003c\/li\u003e\n\t\u003cli\u003eClamp ring easily removed for pump head rotation\u003c\/li\u003e\n\t\u003cli\u003eTough yet lightweight proven design\u003c\/li\u003e\n\t\u003cli\u003e2 mounting options - bulkhead and thru deck models\u003c\/li\u003e\n\t\u003cli\u003eQuick maintenance - Clamp ring easily removed for pump head rotation\u003c\/li\u003e\n\t\u003cli\u003eTypical Uses: bilge pump out, Holding tank pump out, Toilet flush\u003c\/li\u003e\n\t\u003cli\u003eEase of operation - Self priming and spring assisted outlet valve\u003c\/li\u003e\n\t\u003cli\u003eStraight forward installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eManual bilge gusher titan BP4402\u003c\/li\u003e\n\t\u003cli\u003e105 ltrs (28 US gals) per minute\u003c\/li\u003e\n\t\u003cli\u003eEasy to install\u003c\/li\u003e\n\t\u003cli\u003eSelf priming\u003c\/li\u003e\n\t\u003cli\u003eConstructed from non corrosive materials\u003c\/li\u003e\n\t\u003cli\u003eEasily removable clamp for quick maintenance\u003c\/li\u003e\n\t\u003cli\u003eSpring assisted outlet valve for easy priming\u003c\/li\u003e\n\t\u003cli\u003eLightweight pump with a light easy action\u003c\/li\u003e\n\t\u003cli\u003e38mm (1 1\/2\") smooth bore hose connections\u003c\/li\u003e\n\t\u003cli\u003eWeight:1.47kg (31bs 8oz)\u003c\/li\u003e\n\t\u003cli\u003eBP4402 \/ MS8\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/QqZHnQbTCiM\"\u003eYou Tube Clip - Servicing\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/www.whalepumps.com\/marine\/siteFiles\/resources\/docs\/resource-library\/180.15_v2_0115_db2.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/www.whalepumps.com\/marine\/siteFiles\/resources\/docs\/resource-library\/ExplodedView\/MBP_Gusher_titan.pdf\"\u003eExploded View\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003c\/ul\u003e","brand":"Whale","offers":[{"title":"Default Title","offer_id":47319255679253,"sku":"MA-BP4402","price":104.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/s-l1600_10_3d454d47-bd47-4f66-970b-00cb5daf9a02.jpg?v=1700569140"},{"product_id":"whale-bp0350-compac-50-manual-bilge-pump","title":"Whale BP0350 Compac 50 Manual Bilge Pump","description":"\u003cp\u003eLow profile under deck bilge pump \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003etough, proven whale design\u003c\/li\u003e\n\u003cli\u003ecompletely enclosed protected diaphragm\u003c\/li\u003e\n\u003cli\u003e49ltrs (13 us gals) per minute\u003c\/li\u003e\n\u003cli\u003eonly 4 .5ch (119mm) deep for low profile installation under deck or thru bulkhead where space is limited\u003c\/li\u003e\n\u003cli\u003erotatable inlet and outlet nozzles for flexibility\u003c\/li\u003e\n\u003cli\u003eeasily removable clamp ring for quick maintenance\u003c\/li\u003e\n\u003cli\u003equick and easy to fit\u003c\/li\u003e\n\u003cli\u003esupplied complete with deck plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003esuitable for pumping diesel max lift:3m (10ft) max head:4m (13ft) weight:0.9kg (2lb) hose bore:25mm (1 ).\u003c\/span\u003e\u003c\/p\u003e","brand":"Whale","offers":[{"title":"Default Title","offer_id":47319255777557,"sku":"MA-BP0350","price":89.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/ZWHABP0350.jpg?v=1696516107"},{"product_id":"whale-gusher-10-standard-water-bilge-pump-bp3708-ma-bp3708","title":"Whale BP3708 Gusher 10 Mk3 Standard Water Bilge Pump","description":"\u003cul\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e Whale Gusher 10 Standard Water Bilge Pump BP3708.           Ref: MA-BP3708\u003c\/p\u003e\n\n\u003cp\u003eWhale manual diaphragm bilge water transfer pump.  Pumps up to 65 litres per minute (14 gallons).  \u003c\/p\u003e\n\n\u003cp\u003eWhale's long life diecast alloy range - robust designs for extreme conditions. Install Gusher 10 for the long haul.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eDurable Diecast Alloy Bilge Pump\u003c\/li\u003e\n\t\u003cli\u003eRobust design stands up to the toughest marine conditions\u003c\/li\u003e\n\t\u003cli\u003eTop performance- High flow non-choke valves, 65 ltrs (17 US gals) per minute\u003c\/li\u003e\n\t\u003cli\u003e3 mounting options available Bulkhead, floor or thru deck mounting\u003c\/li\u003e\n\t\u003cli\u003eDesigned for simple installation and maintenance\u003c\/li\u003e\n\t\u003cli\u003eEfficiency - Large non-choke valves\u003c\/li\u003e\n\t\u003cli\u003eIdeal for workboats, cruisers, offshore racing\u003c\/li\u003e\n\t\u003cli\u003eEasy pump action - Self priming\u003c\/li\u003e\n\t\u003cli\u003eSuitable for diesel transfer with Nitrile diaphragm (service kit AK3714 available separately)\u003c\/li\u003e\n\t\u003cli\u003eDiecast alloy bilge pump (on deck mounting)\u003c\/li\u003e\n\t\u003cli\u003eRobust - ideal for workboats, cruisers, offshore racing\u003c\/li\u003e\n\t\u003cli\u003eSelf priming with a light and easy pump action\u003c\/li\u003e\n\t\u003cli\u003eUp to 42 ltrs (10 US gals)per minute\u003c\/li\u003e\n\t\u003cli\u003eEasy to install\u003c\/li\u003e\n\t\u003cli\u003eLarge non-choke valves\u003c\/li\u003e\n\t\u003cli\u003eApproved for use in lifeboats\u003c\/li\u003e\n\t\u003cli\u003eSuitable for diesel tranfer with nitrile diaphram\u003c\/li\u003e\n\t\u003cli\u003eDesigned for easy access \u0026amp; easy maintenance\u003c\/li\u003e\n\t\u003cli\u003eSuitable for manual pump out of effluent holding system\u003c\/li\u003e\n\t\u003cli\u003eNitrile diaphram also available\u003c\/li\u003e\n\t\u003cli\u003eHose connections: 38mm\u003c\/li\u003e\n\t\u003cli\u003eWeight:2.26kg\u003c\/li\u003e\n\t\u003cli\u003eMax priming height: 4mtrs\u003c\/li\u003e\n\t\u003cli\u003eMax head height: 4mtrs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/yGwOnDN5BZw\"\u003eYou Tube Clip - Servicing Gusher 10\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/www.whalepumps.com\/marine\/siteFiles\/resources\/docs\/resource-library\/180.07_v3_0217_db.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/www.whalepumps.com\/marine\/siteFiles\/resources\/docs\/resource-library\/ExplodedView\/MBP_Gusher10.pdf\"\u003eExploded View\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003c\/ul\u003e","brand":"Whale","offers":[{"title":"Default Title","offer_id":47319263543573,"sku":"MA-BP3708","price":250.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/bp3708.jpg?v=1696516157"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/collections\/cat-pumps-pumps_ea4c118f-b0e1-44e4-80f7-98852a2f17f5.jpg?v=1791881139","url":"https:\/\/marinescene.co.uk\/collections\/bilge-pumps.oembed?page=4","provider":"Marine Scene","version":"1.0","type":"link"}