{"product_id":"jabsco-junior-puppy-23670-series-bilge-deckwash-pump","title":"Jabsco Junior Puppy 23670 Series Bilge \u0026 Deckwash Pump","description":"\u003cp\u003eThe \u003cstrong\u003eJabsco 23670 Junior Puppy\u003c\/strong\u003e is a bronze-bodied, self-priming flexible-impeller pump delivering approximately 15 litres per minute. Choose 12V model 23670-4003 or 24V model 23670-4103.\u003c\/p\u003e\u003cp\u003eThe continuously rated pump is intended for medium-duty bilge, deckwash and general water-transfer applications. Its simple serviceable design uses a nitrile impeller and stainless-steel shaft, and it must be mounted so the pump head is not positioned above the motor.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Jabsco\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Jabsco 23670 Junior Puppy Bilge and Deckwash Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 23670-4003, 23670-4103\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e CW-23670-4003, CW-23670-4103\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Self-priming flexible-impeller utility pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One selected product or kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Jabsco Junior Puppy Used For?\u003c\/h4\u003e\u003cp\u003eIt transfers water for bilge pumping, deck washing and other medium-duty marine or industrial duties where a self-priming 15 LPM pump is suitable.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Jabsco 23670 Junior Puppy pump in the selected voltage\u003c\/li\u003e\n\u003cli\u003eFactory-fitted nitrile flexible impeller\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eHose or pipework, clips and through-hull fittings\u003c\/li\u003e\n\u003cli\u003eCircuit-protection fuse or breaker\u003c\/li\u003e\n\u003cli\u003eCable extensions and waterproof electrical connectors\u003c\/li\u003e\n\u003cli\u003eControl switch unless specifically listed as included\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Products or Systems Is This Compatible With?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e12V or 24V DC systems according to the selected model\u003c\/li\u003e\n\u003cli\u003e19 mm (3\/4 in) bore hose\u003c\/li\u003e\n\u003cli\u003e3\/8 in BSP female threaded connections\u003c\/li\u003e\n\u003cli\u003eWater-transfer duties compatible with bronze, nitrile and stainless-steel wetted materials\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Do I Select the Correct Model or Confirm Compatibility?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSelect 23670-4003 for 12V or 23670-4103 for 24V\u003c\/li\u003e\n\u003cli\u003eAllow for the model-specific current draw and fuse\u003c\/li\u003e\n\u003cli\u003eConfirm that approximately 15 LPM meets the required duty at the installed head\u003c\/li\u003e\n\u003cli\u003eDo not use for petrol or liquids with a flash point below 37°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eBronze pump body\u003c\/li\u003e\n\u003cli\u003eNitrile flexible impeller\u003c\/li\u003e\n\u003cli\u003eStainless-steel shaft\u003c\/li\u003e\n\u003cli\u003eLip-seal construction\u003c\/li\u003e\n\u003cli\u003eServiceable flexible-impeller design\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eIsolate the electrical supply before installation. Match the pump to the vessel voltage, use the specified circuit protection and cable size, keep electrical joints dry and accessible, and support all connected hose or pipework. Follow the Jabsco installation instructions for mounting orientation, priming and duty cycle.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect the pump, wiring, fuse, ports and connected pipework regularly. Clean any inlet strainer, investigate reduced flow or repeated fuse failure, and replace worn seals, diaphragms or impellers with the correct Jabsco service parts.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eApprox. 15 LPM output\u003c\/li\u003e\n\u003cli\u003e12V and 24V variants\u003c\/li\u003e\n\u003cli\u003eSelf-primes up to 2.5 m\u003c\/li\u003e\n\u003cli\u003e19 mm hose or 3\/8 in BSP connections\u003c\/li\u003e\n\u003cli\u003eContinuously rated medium-duty design\u003c\/li\u003e\n\u003cli\u003eISO 8846 and ISO 8849 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eCan the Junior Puppy run dry?\u003c\/strong\u003e\u003cbr\u003eNo. Flexible-impeller pumps can be damaged by dry running; ensure the pump is primed and the inlet path is clear.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this an automatic bilge pump?\u003c\/strong\u003e\u003cbr\u003eNo. It requires a separate correctly rated switch or control arrangement.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I know whether this part is compatible?\u003c\/strong\u003e\u003cbr\u003eMatch the exact Jabsco model or part number first, then confirm the connection size, voltage, dimensions and application shown in the specification table.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAre installation accessories included?\u003c\/strong\u003e\u003cbr\u003eOnly the components listed under “What Is Included?” are supplied. Hose, wiring, fittings, switches and fasteners are excluded unless stated otherwise.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable class=\"spec-table\" style=\"width:100%;border-collapse:collapse;font-family:Roboto, Arial, sans-serif;background:#ffffff;text-align:center;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:center;font-weight:500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:center;font-weight:500;\"\u003e23670-4003\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:center;font-weight:500;\"\u003e23670-4103\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eJabsco\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eJabsco\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eSelf-priming flexible-impeller utility pump\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eSelf-priming flexible-impeller utility pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eCW-23670-4003\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eCW-23670-4103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eMaximum flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eApprox. 15 LPM\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eApprox. 15 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e13A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e15A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eFlow at 5 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e930 LPH (245 US GPH)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e930 LPH (245 US GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eFlow at 10 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e810 LPH (213 US GPH)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e810 LPH (213 US GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eFlow at 15 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e690 LPH (182 US GPH)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e690 LPH (182 US GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eSelf-priming lift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eUp to 2.5 m\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eUp to 2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e19 mm (3\/4 in) hose or 3\/8 in BSP female\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e19 mm (3\/4 in) hose or 3\/8 in BSP female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e180 x 110 x 90 mm (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e180 x 110 x 90 mm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eReplacement impeller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e9200-0023B\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e9200-0023B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eISO 8846 ignition protection; ISO 8849 bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:center;\"\u003eISO 8846 ignition protection; ISO 8849 bilge-pump standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003cem\u003ePerformance depends on total head, hose condition, voltage at the motor and the condition of the flexible impeller.\u003c\/em\u003e\u003c\/p\u003e","brand":"Jabsco","offers":[{"title":"12v","offer_id":54832707142009,"sku":"ASAP-JAB-23670-4003","price":334.98,"currency_code":"GBP","in_stock":true},{"title":"24v","offer_id":54832707174777,"sku":"ASAP-JAB-23670-4103","price":334.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/23670_jpg.jpg?v=1695911961","url":"https:\/\/marinescene.co.uk\/products\/jabsco-junior-puppy-23670-series-bilge-deckwash-pump","provider":"Marine Scene","version":"1.0","type":"link"}