{"product_id":"rule-24da-360-series-submersible-bilge-pump-with-35a-float-switch-1362-lph","title":"Rule 24DA 360 Series Submersible Bilge Pump With 35A Float Switch - 1362 LPH","description":"\u003cp\u003eThis Rule kit combines a 12V 24DA 360 GPH submersible bilge pump with a 35A Rule-A-Matic float switch, providing automatic bilge-water removal when correctly wired and fused.\u003c\/p\u003e\u003cp\u003eThe kit pairs Rule’s compact 24DA standard bilge pump with the Rule 35A mercury-free float switch. The pump itself is non-automatic; the 35A switch closes the circuit as the water level rises and opens it after the water level falls, creating a conventional automatic bilge-pump system.\u003c\/p\u003e\u003ch4\u003eProduct Identification\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name:\u003c\/strong\u003e Rule 24DA 360 Series Submersible Bilge Pump With 35A Float Switch - 1362 LPH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ part number:\u003c\/strong\u003e 24DA pump + 35A float switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Scene SKU:\u003c\/strong\u003e ASAP-JAB-24DA-35A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Standard submersible bilge pump \/ Bilge-pump float switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated open flow:\u003c\/strong\u003e 360 GPH (1,363 LPH; approx. 23 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem voltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic control:\u003c\/strong\u003e Yes - via the included Rule 35A float switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose size:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump current draw:\u003c\/strong\u003e 2.1A at 12V; 2.4A at 13.6V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended pump fuse:\u003c\/strong\u003e 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity supplied:\u003c\/strong\u003e One pump and one float switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is the Rule 24DA and 35A Bilge Pump Kit Used For?\u003c\/h4\u003e\u003cp\u003eThis kit is used to install an automatic 12V bilge-pumping system in smaller craft and confined bilge spaces. The 360 GPH pump removes nuisance water, while the float switch provides automatic on\/off control.\u003c\/p\u003e\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOne Rule 24DA 360 GPH submersible bilge pump\u003c\/li\u003e\n\u003cli\u003eOne Rule 35A Rule-A-Matic float switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhat Is Not Included?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDischarge hose, through-hull fitting and hose clips\u003c\/li\u003e\n\u003cli\u003ePanel switch\u003c\/li\u003e\n\u003cli\u003eCorrectly rated fuse, cable extensions and waterproof connectors\u003c\/li\u003e\n\u003cli\u003eInstallation fasteners unless present in the retail package\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eWhich Boats and Bilge Systems Is This Kit Suitable For?\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFor 12V DC marine electrical systems.\u003c\/li\u003e\n\u003cli\u003ePump connects to 19 mm (3\/4 in) ID discharge hose.\u003c\/li\u003e\n\u003cli\u003e35A switch is rated up to 14A at 12V; the included 24DA pump draws substantially less than this limit.\u003c\/li\u003e\n\u003cli\u003eSuitable for conventional automatic control; an optional 12V three-way panel switch may be added for automatic\/off\/manual control.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHow Do the Pump and Float Switch Work Together?\u003c\/h4\u003e\u003cp\u003eThe 24DA pump provides the water-removal flow, while the 35A float switch opens and closes the pump circuit as the bilge-water level rises and falls. The pump is not independently automatic; automatic operation depends on correct float-switch installation and wiring.\u003c\/p\u003e\u003ch4\u003eHow Do I Confirm This Kit Is Suitable?\u003c\/h4\u003e\u003cp\u003eCheck the electrical system, available bilge space, discharge route and switching capacity before installation:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem voltage:\u003c\/strong\u003e 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump rated open flow:\u003c\/strong\u003e 360 GPH (1,363 LPH; approx. 23 litres\/minute)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge hose:\u003c\/strong\u003e 19 mm (3\/4 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat-switch maximum current:\u003c\/strong\u003e 14A at 12V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump ON level:\u003c\/strong\u003e Approx. 51 mm (2 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump OFF level:\u003c\/strong\u003e Approx. 19 mm (3\/4 in)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eConstruction and Design\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow prevention:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal protection:\u003c\/strong\u003e Built-in thermal cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e CE; ISO 8849 marine bilge-pump standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting base:\u003c\/strong\u003e Removable for cleaning and servicing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation and Safety\u003c\/h4\u003e\u003cp\u003eMount the pump at the lowest practical point of the bilge and install the float switch nearby on a level surface where it can move freely. The pump and switch must be wired through the specified fuse using marine-grade cable and waterproof connections positioned above the maximum bilge-water level. Test switch movement and pump operation after installation and at regular service intervals.\u003c\/p\u003e\u003ch4\u003eMaintenance\u003c\/h4\u003e\u003cp\u003eInspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemove debris from the strainer and impeller area.\u003c\/li\u003e\n\u003cli\u003eInspect the discharge hose, clips, through-hull and anti-siphon arrangement.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, fuse, terminals and control switch for heat, corrosion or damage.\u003c\/li\u003e\n\u003cli\u003eKeep the automatic sensor or float-switch movement clear of oil, dirt and debris.\u003c\/li\u003e\n\u003cli\u003eTest manual and automatic operation after cleaning or service.\u003c\/li\u003e\n\u003cli\u003eReplace damaged components rather than operating an unreliable bilge system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eComplete pump-and-float-switch combination for automatic operation\u003c\/li\u003e\n\u003cli\u003e360 GPH (1,363 LPH) nominal open-flow pump capacity\u003c\/li\u003e\n\u003cli\u003e12V DC operation\u003c\/li\u003e\n\u003cli\u003e19 mm (3\/4 in) discharge connection\u003c\/li\u003e\n\u003cli\u003ePump includes thermal cut-off and easy-clean strainer\u003c\/li\u003e\n\u003cli\u003e35A switch is mercury-free, ignition protected and serviceable from its removable base\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eIs the Rule 24DA pump automatic by itself?\u003c\/strong\u003e\u003cbr\u003eNo. Automatic control is provided by wiring the included Rule 35A float switch into the pump circuit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat hose size is required?\u003c\/strong\u003e\u003cbr\u003eUse 19 mm (3\/4 in) ID bilge hose and secure it with suitable marine-grade hose clips.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the kit include a panel switch?\u003c\/strong\u003e\u003cbr\u003eNo. A compatible 12V panel switch can be added separately where manual override is required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat fuse should be used?\u003c\/strong\u003e\u003cbr\u003eUse the pump manufacturer’s recommended 4A fuse and follow the installation diagram. The float switch rating is a maximum switching capacity, not the required fuse size.\u003c\/p\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100%; border-collapse: collapse; font-family: Roboto, Arial, sans-serif; background: #ffffff; text-align: center;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e24DA\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: center; font-weight: 500;\"\u003e35A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eProduct category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eStandard submersible bilge pump\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBilge-pump float switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMarine Scene SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eASAP-JAB-24DA\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRated open flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e360 GPH (1,363 LPH; approx. 23 litres\/minute)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eAutomatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eNo - use a suitably rated float switch and\/or panel switch for automatic control\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2.1A at 12V; 2.4A at 13.6V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eRecommended fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e4A\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 1 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e265 GPH (1,003 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eFlow at 2 m head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e190 GPH (719 LPH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum recommended discharge head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e2 m\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e99 x 74 mm (H x W)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eDischarge hose size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e19 mm (3\/4 in)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eReplacement strainer part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e1231R\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eBackflow prevention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eThermal protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eBuilt-in thermal cut-off\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eIgnition protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eCE; ISO 8849 marine bilge-pump standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eKit SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eASAP-JAB-24DA-35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSystem voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMaximum switched current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e14A at 12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003ePump ON level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eApprox. 51 mm (2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003ePump OFF level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eApprox. 19 mm (3\/4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eWire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e16 AWG marine-grade blocked wire; approx. 712 mm long\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eSwitch type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eMercury-free snap switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e\u003cstrong\u003eMounting base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; text-align: center;\"\u003eRemovable for cleaning and servicing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cem\u003eFlow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.\u003c\/em\u003e\u003c\/p\u003e","brand":"Rule","offers":[{"title":"Default Title","offer_id":47309871677717,"sku":"ASAP-JAB-24DA-35A","price":81.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0773\/6151\/2725\/products\/24da-35a_jpg.jpg?v=1698135288","url":"https:\/\/marinescene.co.uk\/products\/rule-24da-360-series-submersible-bilge-pump-with-35a-float-switch-1362-lph","provider":"Marine Scene","version":"1.0","type":"link"}