Skip to product information
1 of 1

Rule 02 / 03 1500 Series Submersible Bilge Pump - 1500 GPH

Rule 02 / 03 1500 Series Submersible Bilge Pump - 1500 GPH

SKU: ASAP-504102

The Rule 02 / 03 is a non-automatic submersible bilge pump rated at 1,500 GPH (5,678 LPH; approx. 95 litres/minute). It is designed for medium-capacity bilge drainage on yachts and motor cruisers, uses 29 mm (1-1/8 in) discharge hose and requires a suitably rated float switch and/or panel switch for automatic operation.

Regular price £194.98
Regular price Sale price £194.98
Sale Sold out
Tax included. Shipping calculated at checkout.
Voltage

Delivery available  |  lead times vary

Collection available  |  usually ready in 2-4 days

Description

The Rule 02 / 03 is a non-automatic submersible bilge pump rated at 1,500 GPH (5,678 LPH; approx. 95 litres/minute). It is designed for medium-capacity bilge drainage on yachts and motor cruisers, uses 29 mm (1-1/8 in) discharge hose and requires a suitably rated float switch and/or panel switch for automatic operation.

The Rule 02 / 03 removes nuisance water from a boat bilge using a fully submersible centrifugal pump. The snap-lock strainer provides access to the impeller area for routine cleaning, while the stainless-steel shaft, blocked marine wiring, corrosion-resistant housing and built-in thermal cut-off are intended for permanent marine installation.

Product Identification

  • Brand: Rule
  • Product name: Rule 02 / 03 1500 Series Submersible Bilge Pump - 1500 GPH
  • Model / part number: 02 / 03
  • Marine Scene SKU: CW-02 / CW-03
  • Product category: Standard submersible bilge pump
  • Rated open flow: 1,500 GPH (5,678 LPH; approx. 95 litres/minute)
  • Voltage: 12V DC / 24V DC
  • Automatic operation: No - use a suitably rated float switch and/or panel switch for automatic control
  • Discharge hose size: 29 mm (1-1/8 in)
  • Current draw: 4.0A at 12V; 4.8A at 13.6V / 2.3A at 24V; 3.5A at 27.2V
  • Recommended fuse: 10A / 4A
  • Quantity supplied: One pump

What Is the Rule 02 / 03 Bilge Pump Used For?

This pump is used for medium-capacity bilge drainage on yachts and motor cruisers. It is a standard, non-automatic pump: power must be controlled by a separate Rule float switch, compatible panel switch or another correctly rated control device.

What Is Included?

  • One Rule submersible bilge pump
  • Integral or snap-lock strainer base
  • Factory-fitted marine-grade electrical leads

What Is Not Included?

  • Float switch or control panel
  • Discharge hose, through-hull fitting and hose clips
  • Cable extensions, waterproof connectors and circuit-protection fuse
  • Installation hardware not supplied with the packaged pump

Which Boats and Bilge Systems Is This Pump Suitable For?

  • Suitable for medium-capacity bilge drainage on yachts and motor cruisers.
  • Connect to 29 mm (1-1/8 in) discharge hose and a correctly positioned above-waterline discharge outlet.
  • Choose the variant that matches the vessel electrical system: 12V / 24V.
  • Use only with switching, cabling and circuit protection rated for the pump voltage and current.

Is a Separate Float Switch Required?

No - use a suitably rated float switch and/or panel switch for automatic control

Which Voltage Should I Choose?

Choose the version that matches the vessel electrical system: 12V DC / 24V DC. A pump must only be connected to its stated DC supply voltage.

How Do I Select the Correct Pump?

Confirm the complete installation rather than selecting by nominal GPH rating alone:

  • Supply voltage: 12V DC / 24V DC
  • Rated open flow: 1,500 GPH (5,678 LPH; approx. 95 litres/minute)
  • Discharge hose: 29 mm (1-1/8 in)
  • Installed space: 152 x 108 mm (H x W)
  • Circuit protection: 10A / 4A
  • Flow at 1 m head: 1,200 GPH (4,542 LPH)
  • Flow at 2 m head: 680 GPH (2,574 LPH)

Does the Published Flow Equal the Installed Flow?

No. The nominal capacity is an open-flow rating. Actual output reduces as discharge head, hose length, bends, restrictions and electrical voltage drop increase. Use the published flow-at-head figures where available and keep the discharge route as short and unrestricted as practical.

Construction and Design

  • Replacement strainer part number: 278
  • Backflow prevention: No integral non-return valve stated
  • Thermal protection: Built-in thermal cut-off
  • Ignition protection: Yes
  • Standards: CE; ISO 8849 marine bilge-pump standard

Installation and Safety

Mount the pump at the lowest practical point of the bilge while retaining access for strainer cleaning. Keep all electrical joints above the maximum anticipated bilge-water level, fit the manufacturer-specified fuse close to the power source, minimise hose length and bends, and route the discharge to prevent siphoning or backflow. Test both manual and automatic control after installation and during routine vessel checks.

Maintenance

Inspect and test the complete bilge-pump system regularly and before extended passages. Reduced flow, repeated fuse failure, unusual noise or slow switching requires investigation before the vessel is used.

  • Remove debris from the strainer and impeller area.
  • Inspect the discharge hose, clips, through-hull and anti-siphon arrangement.
  • Check the wiring, fuse, terminals and control switch for heat, corrosion or damage.
  • Test manual and automatic operation after cleaning or service.
  • Replace damaged components rather than operating an unreliable bilge system.

Key Features

  • Nominal open-flow capacity: 1,500 GPH (5,678 LPH; approx. 95 litres/minute)
  • Non-automatic design for use with a separate switch
  • Easy-clean strainer base and accessible impeller cavity
  • Built-in thermal cut-off
  • Marine-grade blocked wiring and stainless-steel shaft
  • Ignition protected; CE and ISO 8849 compliant
  • 12V model 02 and 24V model 03 options

Frequently Asked Questions

Is this Rule bilge pump automatic?
No. It is a standard pump and requires a separate float switch and/or panel switch for automatic operation.

How do I choose between the available variants?
Select the model that matches the vessel supply voltage. Do not connect a 12V / 24V pump to a different-voltage circuit.

Will the pump deliver the full rated output after installation?
Not necessarily. The published rating is an open-flow figure; actual delivery falls as vertical head, hose length, bends, restrictions and voltage drop increase.

Can this pump replace routine bilge inspection?
No. A bilge pump is one part of a vessel water-management system. Inspect the bilge, hoses, wiring, discharge outlet and switch regularly.

Specifications

Specification 02 03
Brand Rule Rule
Product category Standard submersible bilge pump Standard submersible bilge pump
Marine Scene SKU CW-02 CW-03
Rated open flow 1,500 GPH (5,678 LPH; approx. 95 litres/minute) 1,500 GPH (5,678 LPH; approx. 95 litres/minute)
Voltage 12V DC 24V DC
Automatic operation No - use a suitably rated float switch and/or panel switch for automatic control No - use a suitably rated float switch and/or panel switch for automatic control
Current draw 4.0A at 12V; 4.8A at 13.6V 2.3A at 24V; 3.5A at 27.2V
Recommended fuse 10A 4A
Flow at 1 m head 1,200 GPH (4,542 LPH) 1,200 GPH (4,542 LPH)
Flow at 2 m head 680 GPH (2,574 LPH) 680 GPH (2,574 LPH)
Maximum recommended discharge head 2 m 2 m
Dimensions 152 x 108 mm (H x W) 152 x 108 mm (H x W)
Discharge hose size 29 mm (1-1/8 in) 29 mm (1-1/8 in)
Replacement strainer part number 278 278
Backflow prevention No integral non-return valve stated No integral non-return valve stated
Thermal protection Built-in thermal cut-off Built-in thermal cut-off
Ignition protection Yes Yes
Standards CE; ISO 8849 marine bilge-pump standard CE; ISO 8849 marine bilge-pump standard

Flow ratings are nominal open-flow figures. Installed output will reduce as discharge head, hose length, bends, restrictions and supply-voltage loss increase.

Specification

Specification 02 03
Brand Rule Rule
Product category Standard submersible bilge pump Standard submersible bilge pump
Marine Scene SKU CW-02 CW-03
Rated open flow 1,500 GPH (5,678 LPH; approx. 95 litres/minute) 1,500 GPH (5,678 LPH; approx. 95 litres/minute)
Voltage 12V DC 24V DC
Automatic operation No - use a suitably rated float switch and/or panel switch for automatic control No - use a suitably rated float switch and/or panel switch for automatic control
Current draw 4.0A at 12V; 4.8A at 13.6V 2.3A at 24V; 3.5A at 27.2V
Recommended fuse 10A 4A
Flow at 1 m head 1,200 GPH (4,542 LPH) 1,200 GPH (4,542 LPH)
Flow at 2 m head 680 GPH (2,574 LPH) 680 GPH (2,574 LPH)
Maximum recommended discharge head 2 m 2 m
Dimensions 152 x 108 mm (H x W) 152 x 108 mm (H x W)
Discharge hose size 29 mm (1-1/8 in) 29 mm (1-1/8 in)
Replacement strainer part number 278 278
Backflow prevention No integral non-return valve stated No integral non-return valve stated
Thermal protection Built-in thermal cut-off Built-in thermal cut-off
Ignition protection Yes Yes
Standards CE; ISO 8849 marine bilge-pump standard CE; ISO 8849 marine bilge-pump standard
View full details